Zip Heater HydroTap G4 Скачать руководство пользователя страница 11

802006UK  BCS Residential User Guide - Aug 2015- V2.01              Page 11 of 28

 

Tap lights

Warning light 

all models

Flashing warning light

When the indicator light flashes fast and 

continuous, a system fault has occurred.

Check for details on the faults screen. If 

unable to rectify, call a qualified service 

agent.

See System information, page 14 and 

Service, page 18.

Filter light 

Classic and Elite

Filter light off

This indicates the filter is operating within its 

normal specified lifespan.

Filter light flashing slowly

The light will flash slowly when the filter is 

due for replacement and the LCD will show 

‘Filter Change. See ‘To change the filter’ 

page 25

Filter lights 

Arc / Cube

All three tap lights (Safety, Select and 

Indicator light) will flash every

10 seconds, indicating a filter change is 

required.

Reset the filter light

See Filter reset page 16

Red warning 

light

Filter light

Elite

Indicator light

Safety 

Lock

Select light

Arc / Cube

Classic

Filter 

light

Содержание HydroTap G4

Страница 1: ...802006UK BCS Residential User Guide Aug 2015 V2 01 Page 1 of 28 ZIP HydroTap G4 User Guide Affix model number label here 802006UK...

Страница 2: ...p safety Page 3 Tap operation Pages 4 to 9 Safety sensor calibration Page 10 Tap lights Page 10 to 11 LCD screen menu Pages 12 to 25 Filter maintenance Pages 25 to 26 Changing the CO2 cylinder Page 27...

Страница 3: ...r touch the CHILLED button Elite keep both fingers in position for a period of approximately ten seconds The safety lock indicator light will illuminate Classic flash momentarily Elite To deactivate t...

Страница 4: ...ssic Depress the red BOILING lever while simultaneously covering the safety lock button with a second finger These two actions need to occur within 2 seconds for the successful dispensing of boiling w...

Страница 5: ...essing the blue CHILLED lever allows the dispensing of chilled water Pulling forward the blue CHILLED lever allows the tap to operate in a no touch mode Water will flow from between 5 and 15 seconds t...

Страница 6: ...he forward direction and when released will return to the off position When rotated in the reverse direction the tap operates in a POT FILL mode Water will flow from between 5 and 15 seconds This is u...

Страница 7: ...t the step The levers have to be manually returned to the off position Operate both levers together To dispense sparkling water Elite Classic Indicator light Safety Lock Arc Cube Select button Elite T...

Страница 8: ...ature will be dependant on the temperature of the incoming cold water Increase flow Decrease flow Cold Hot 3 Tap operation Classic mixer Arc mixer Cube mixer Arc Cube mixer taps Moving the lever away...

Страница 9: ...he hot direction is marked with a red dot and the cold direction with a blue dot for dispensing cold to warm water Lifting the lever up will decrease the flow rate and lowering the lever will increase...

Страница 10: ...sition Pull both levers forward Safety sensor Tap lights Blue lights Red lights Blue CHILLED water lights not available on Elite Continually illuminated This indicates that the temperature of the chil...

Страница 11: ...and Elite Filter light off This indicates the filter is operating within its normal specified lifespan Filter light flashing slowly The light will flash slowly when the filter is due for replacement a...

Страница 12: ...ble messages in status window Status Information Notes Safety OFF Product is in normal operation mode Safety ON Safety lock is activated Refer to section G Safety System Fault Product has one or more...

Страница 13: ...ling calibration Booster Purge CO2 Lux sensor calibration Start Stop Internal External Calibration options Enable Disable Start Stop C Service Password protected D Security Enable password Set passwor...

Страница 14: ...lts to check the fault information Press Event Log to view system events Press button for the previous menu Press Product Info to view the current product serial no Press button for the previous menu...

Страница 15: ...black carbon particles this is normal Once the filter flush has finished press the STOP button to display the main menu Sub menu 1 Filter flush 2 Filter reset 3 Boiling calibration 4 Booster 5 CO2 pu...

Страница 16: ...ater units may vent steam from the tap spout Take care to avoid personal injury whenever this occurs Press the MENU button for main menu Press the Install button Press the Booster button In the next s...

Страница 17: ...on for main menu Press the Install button Press the Purge CO button In the next screen press the START button to commence the purging process Wait for the water to stop flowing through the tap Wait a...

Страница 18: ...Zip technician Please contact your Zip service provider for further assistance G4 HydroTap G4 Password screen Note In UK call a licensed electrician plumber or call Zip Heaters by Telephone 0845 6 00...

Страница 19: ...etooth to operate the product remotely Not yet available LCD screen operation section F To set a password Press the MENU button for main menu Press the Security button Press Enable Password Enter a 4...

Страница 20: ...the Setting button Press the Date Time button Choose 12 hour mode or 24 hour mode by pressing the square button The selected mode will be displayed in dark grey colour with a tick box on the right Pre...

Страница 21: ...adjust filter life and edit filter usage To edit the filter usage This function is to reset the filter change display after a filter has reached the end of its life see page 25 Filter maintenance Pre...

Страница 22: ...Hr OFF OFF OFF Lux Sensor 680 C Dark N A Sleep 680 C ON Lux Sensor OFF Dark N A OFF OFF OFF Lux Sensor or 2 Hr 680 C Dark 2 Hr Sleep 680 C ON Lux Sensor or 2 Hr OFF Dark 2 Hr OFF OFF OFF Disable N A N...

Страница 23: ...fic time To activate On Off modes Press the MENU button for main menu Press the Settings button Enter your 4 digit password and press Enter Press the Energy Modes button Press the On Off Modes Menu bu...

Страница 24: ...and Elite The HydroTap G4 is equipped with a safety mode that allows for additional safety protection if needed Hot isolation do not enable with Arc Cube To allow safety changes select YES on the saf...

Страница 25: ...r Open the door of the Command CenteTM Relieve system pressure via the filter flush stop cock a quick open and close will do Use the bucket to catch the discharge Grasp filter cartridge depress the re...

Страница 26: ...five minutes before consumption Caution A small amount of water will drip as the cartridge is removed Do not tilt the cartridge as water may spill from it if tilted Unpack replacement cartridge and r...

Страница 27: ...on clockwise and adjust to 2 7 bar green zone on dial Check all joints for gas leaks using a sponge and soapy water Purge the gas lines see CO2 purge page 17 Changing the CO2 cylinder General cleanin...

Страница 28: ...display this icon on the home screen See page 22 for details Heater is in off mode When this icon is displayed no power is being supplied to the heating element See page 22 for Energy Mode options Fi...

Отзывы: