Instruction Manual

The following hazards may impact the proper functioning of 
the equipment: e.g. putting stress on the connection devices 
due to sharp edges, cuts, abrasion, slack rope, chemical, 
electric or climatic impact, extreme temperatures, swinging 
movement in the event of a fall. The connection devices, 
therefore, should always be inspected prior to use and if 
necessary, an edge protector must be provided. 

The anchor device may be used in frosty conditions provided 
the device was installed in frost-free conditions. 

3. Requirements for the use and for the user of
Fallnet

®

 SR

The anchor point Fallnet

®

 SR must only be used by persons

who have been instructed in the safe use of the equipment,
who have the necessary knowledge and who, in terms of their
health, are capable of using the equipment (e.g. no impairment
due to medication, alcohol abuse, coronary or circulatory
problems etc.).
The user is to be instructed such that s/he will carry out the
following visual and manual inspections of the anchor point

before each use:

- manual tensile loading and visual inspection of the visible

stainless steel components, the support and the anchor eye

- visual inspection of the load height

Indications that the good working condition of the 

anchor point is restricted could be: 

- the stainless steel parts (support and anchor eye) are

deformed, weakened, soiled or are not in their original
condition.

- the anchor point yields slightly when pulled
- there is an uneven level of material around the anchor point, 

e.g. as a result of drifting

- the black grids are visible.
- Objects (e.g. also concrete slabs) in the area of the anchor

 

point (radius of at least 0.5 m) that would prevent the
supports folding over as planned.

If there are concerns about the safe condition or the pro-
per functioning of the anchor device, it must not be used 
and the builder/the owner must be notified.

Under no circumstances should the device be used until 
the situation has been clarified!

The individual anchor points are to be used in accordance 
with the plan for use. If there is no utilisation plan available, 
the length of the connection device of the PSA must always be 
adjusted such that a possible fall is prevented or a swinging 
fall does not result in impact. Prior to use, an emergency plan 
must be available in which all possible occupational emer-
gency situations are addressed. 

At the request of the client/owner, an inspection of the 
proper functioning of the entire safety equipment is to be 
carried out:

 

 

1. at least once a year
2. where required, e.g. if there is doubt about the proper

functioning of the equipment (see “Indications of

restricted functioning”)

3. after 10 years a complete inspection of the system

Fallnet

®

 SR is to be carried out by the manufacturer.

The equipment must only be inspected by persons qualified 

to do so and details of all inspections must be recorded in the 

inspection chart.
It must also include the works listed under “Regular inspections” 
(page 7). The relevant check list is available in PDF from the 
manufacturer.

Attention:

After a fall arrest event, Fallnet

®

 SR must be removed from 

service immediately. Further use of the equipment is not 
permitted. The product Fallnet

®

 SR must only be used for the 

purpose and application as described. The manufacturer 
accepts liability for the product within the framework of 
applicable statutory requirements.

 

The manufacturer accepts no liability for any other deviating 
use of the product. Furthermore, the manufacturer accepts 
no liability where the Installation Manual and the Instruction 
Manual have been insufficiently adhered to. We wish to state 
explicitly that, regardless of product liability, ZinCo shall only 
assume liability for the consultancy process where installation 
has been carried out in line with ZinCo planning. Installation 
without planning carried out by ZinCo is at your own risk.

Where the anchor point Fallnet

®

 SR is sold in another country, 

the technician / user must make available a copy of the 

Installation / Instruction Manual and the Inspection Chart in 

the language of that country.

4. Label

Manufacturer:

Zinco GmbH 

Type:

Fallnet

®

 SR

Standard

:

EN 795:2012 Type E

Year manufactured:

date of manufacture (year) 

Serial no.:

 ................. 

Max. 1person:

 

max. number of users

The notified body nominated for certification

Note that the Instruction Manual is to be observed

Fall protection equipment only to be used with a

 

      fall absorber

5.

 

Details of manufacturer and testing institute

 

Manufacturer:

ZinCo GmbH, Lise-Meitner-Strasse 2
72622 Nuertingen, Germany
Phone: +49 (0) 7022 6003-0 

 

Email: [email protected]
www.zinco-greenroof.com

Testing institute: 

DEKRA EXAM GmbH
Dinnendahlstrasse 9
44809 Bochum, Germany

 

Notified body N.B. 0158

Содержание Fallnet SR

Страница 1: ...Fallnet SR Installation and Instruction Manual and Inspection...

Страница 2: ...d min 110 kg m 3 The grid must fully cover the base plate and the vertical locking tabs must engage the adjacent elements Installation Manual Page 3 Instruction Manual Page 5 Details on Manufacturer P...

Страница 3: ...at the bulk material to be used as the load on the Fallnet SR extends at least 50 cm beyond all four edges of the grid elements Important The Fallnet SR must always be in direct contact with the load...

Страница 4: ...installation documentation is available in PDF from the manufacturer On completion of installation copies of the document are to be given to the client and are to be retained on the property for subs...

Страница 5: ...nly be used for a roof pitch of maximum 5 it must only be installed on a suitable subsurface i e either on a filter sheet multi course build up or on a protection mat or layer single course build up s...

Страница 6: ...fall is prevented or a swinging fall does not result in impact Prior to use an emergency plan must be available in which all possible occupational emer gency situations are addressed At the request of...

Страница 7: ...carried out by suitably qualified personnel who have been authorised by the manufacturer and are to be recorded on the rear side of this inspection chart The following inspection works are required vi...

Страница 8: ...Inspection Chart Fallnet SR Overview of documentation and plan of inspection works Building Inspection Date Address Authorised company person Comments reason for inspection defects identified repair...

Отзывы: