Decoder-Update-und-Sound-Loading devices MXULF, MXULFA                                                       Page 5 

In case of more than one MS-update file on the flash drive, only the first file is shown in the list. After 
pressing 

Button 1

 the MXULF automatically displays the list of update files on the flash drive. Select 

the appropriate file with the scrolling wheel and start the update by pressing 

Button 1

. The following 

procedure is described above. 

Updating a MS-

decoder is also possible via the menu item “MS Software Update”.  

- MS decoders with software lower than or equal to 4.08:

 

MS440 and MS450 decoders with a software lower than or equal to 4.08 can only be updated with a 
specific software for the corresponding decoder type. This software is "MS440C_4.xx.zsu", 
"MS440D_4.xx.zsu" or “MS450_4.xx.zsu”, where xx describes the subversion of software 4. 
The update is executed by scrolling through the MXULFA’s menu (press and hold 

R-key

 for 3 seconds) 

and select menu item “MS SW PowCycle”. After pressing the 

R-key

, the update is started. The MXUL-

FA display shows the progress of the update and the decoder type. The process is completed with the 
notification “OK 1 (1) ready -> R”. LED 1 remains yellow. 

To return to main display: Press the 

R-key

. After a few seconds, the MXULF is ready for a new update. 

Unplug the flash drive if this is not wanted.

 

 

Decoder of another manufacturer

 is connected

   

as soon as decoder is identified  

 LED (track) turns 

yellow

 

Display of company name (ESU, ...) or “Hst xxx” (according to CV #8). Decoders of other manufactur-
ers do NOT have SW subversions, but only the version according to CV #7. In those cases, software 
updates and sound loading is not possible. 

In case first the decoder and then the flash drive are connected to the MXULF, first the decoder data 
and then the contents of the flash drive is displayed. Of course it is possible to display the contents of 
the flash drive after displaying the decoder data. Unplug and re-plug the flash drive.  

 

Failure: 

LED (1 or 2)

  

flashes red.

 

The MXULFA shows the failure of a software update on the display with: 

- "Decoder not found": Connection to the decoder could not be established. If the decoder is connected to 
the MXULFA try again. It is also possible that the decoder is locked. Program CV #144 = 0 

- no response -

> R”: the MS decoder does not send feedback to the MXULFA. MX update files can be on 

the flash drive. 

Via ZSP (ZIMO Sound Programmer)

 

It is also possible to update the software of a MX decoder with ZSP (ZIMO Sound Programmer) online. 
How to operate ZSP is described in the ZSP instruction manual: 

http://www.zimo.at/web2010/documents/ZSP%20Bedienungsanleitung_V3.3.pdf

 

Currently (06.2020), this update process is not possible for MS decoders. 
 

  

6. Decoder sound loading 

Loading sound via SUSI interface

 

MXULF-SW 0.64.01 and higher, and decoder-SW 35.00 

Loading sound to MX decoders takes about 3 - 4 min, to MS decoders about 5-6 minutes at full memory 
use. This concerns decoders with PluX, Next18 or MTC interfaces as well as large-scale decoders. 

In this case, the large-scale decoder is connected via its own SUSI interface to the SUSI plug of the 
MXULF with the red SUSI cable; a “small decoder” (PluX, Next18 or MTC) is plugged into the MXTAPS/V 
with this interface and connected via the red SUSI cable to the MXULF. Several decoders can be connect-
ed in parallel. 

NO further supply of the decoder (or decoders) is necessary; 

the connection “Schiene” (track) does not 

have to be connected (see description below). 

Wired decoders:

 SUSI-interface on solder pad; see decoder instruction manual regarding positions. 

Via flash drive 

The sound file (.zpp) is in the root directory of the flash drive. It is plugged into the USB port of the 
MXULFA: 

Display of the MXULFA                      

 NO *.zsu File

     

 

 

 

 

 

          if 

decoder sound project

 identified

 

LED 2 turns yellow

 

 Harzkamel-13.zpp 

         

 displaying the name of the sound project found on the flash drive. 

                                        

 

 If there are more of the same sort, the newest is displayed. 

To download via SUSI, open the MXULFA menu by pressing the 

R-key

 

for 3 seconds. Select “ SUSI 

SOUND Load “ with the scrolling wheel and press the 

R-key

 to start loading.       

 

  

 

 

The MXULFA display shows the download progr

ess and its completion with “SUSI 100%”. LED 2 re-

mains green.  

To return to main display: Press the 

R-key

. After a few seconds, the MXULF is ready for a new loading 

procedure. Unplug the flash drive if this is not wanted. 

 

In case there are more than one sound projects on the flash drive, they can be selected with the scroll-
ing wheel and the 

R-key

. Files of another type are irrelevant. If there are no sound files found on the 

flash drive, the MXULFA displays “No file Repeat -> R”. 

If it fails, the display s

hows “Neustart-Fehler -> R” (Restart error -> R). Return to the menu by pressing 

the 

R-key

 on the MXULFA to repeat the process or restart the device. Sometimes it also helps to dis-

connect the MXULFA from power before starting a download or another operation. 

Sometimes it is useful to disconnect the MXULFA from power before starting a download.  

Via ZSP (ZIMO Sound Programmer) 

It is also possible to download a sound project from the ZIMO ZSP software with an USB cable connect-
ing PC / Laptop and the MXULFA. 

The MXULFA is connected via an USB cable to the computer with ZSP (or ZPP Config) installed. The 
MXULFA always has to be connected to power, a flash drive must not be connected in this case. How to 
operate ZSP is described in the ZSP instruction manual: 

http://www.zimo.at/web2010/documents/ZSP%20Bedienungsanleitung_V3.3.pdf

 

 

 

 

Loading sound via “tracks”

 

Downloading a sound project via a SUSI connection is sometimes not possible due to a missing interface. 6 
or 8 pole (NEM 651, 652) decoders do not have SUSI contacts, so a sound project has to be downloaded 
via “track” pins/wires (red and black wires). 

NOTE: In case of older SW versions of the MXULF, the power supply and the flash drive have to be 
connected to the MXULF before the decoder is connected. 

NOTE:  when  loading  a  sound  project  via  SUSI  onto  a  MS  decoder,  the  LEDs  LV  and  LR  of  the 
MXTAPS/V flash. 

Содержание MXULF

Страница 1: ...decoders MX820 MX821 6 8 Driving operation with MXULFA 6 9 Programming reading CVs SERV PROG OP PROG 7 10 Read program load code 7 11 Decoder connection board MXTAPS V 8 12 Using the MXULF A with the...

Страница 2: ...lay status and processes the MXULFA ad ditionally is equipped with a 2 x 16 characters display The LEDs on the MXULF are sufficient for simple updating and sound loading operations for driving op erat...

Страница 3: ...Decoder Update und Sound Loading devices MXULF MXULFA Page 3...

Страница 4: ...dark only decoder SW container files found LED 1 turns yellow LED 2 remains dark only decoder sound projects found LED 1 remains dark LED 2 turns yellow container file and sound project found LEDs 1...

Страница 5: ...This concerns decoders with PluX Next18 or MTC interfaces as well as large scale decoders In this case the large scale decoder is connected via its own SUSI interface to the SUSI plug of the MXULF wit...

Страница 6: ...the digital command station and sends the new software to all acces sory decoders Every single accessory decoder then has the possibility to request a repetition by negative acknowledgements until all...

Страница 7: ...PoM Programming on the Main To activate one of the programming modes press and hold the R key 3 sec to open the menu scroll to SERV PROG or OP PROG and press the R key to change to the programming met...

Страница 8: ...IMO decoder test and connection boards are best used wit MXULF and MXULFA as well as ZIMO command stations especially MX10 but also with older ZIMO digital command stations and devices of other manufa...

Страница 9: ...XULFA 2 pole cable from Schiene MXULFA to SCHIENE MXTAP on the MXULFA a decoder update was just started according to the display the decoder software is loaded from a flash drive MXTAPV not MXTAPS wit...

Страница 10: ...puiter and the directory opened e g Windows Explor er the contents appears Screenshot Starting ZIMO Installer exe by double click Screenshot Installing the MXULF driver via the first item on the windo...

Страница 11: ...ngs in where either suggested or in the drop down menu you select the COM Port with the corresponding reference ZIMO Interface MX31ZL or MXULF P F u Sch provides Options under Parameter where you can...

Страница 12: ...ZIMO Elektronik GmbH guarantees its products for 24 months from the date of purchase with proof of pur chase from a ZIMO contractor The warranty covers the repair or replacement of defective parts ZIM...

Отзывы: