10
6.1.1 Wiring diagram sensor system
Sensor plug connection M8 3-pin:
4
1
3
Graphical symbol for sensor in storage position
2 sensors in inspection position connected in series
+
-
1
3
4
Power Supply
Safety Input
+
-
1
3
4
Power Supply
Safety Input
+
-
1
3
4
Safety Input
6.1.2 Adjust the sensors in the inspection
position
9
bl
►
Bring the markings on the locking elements
of the MATCH gripper to the position of
the front markings of the MATCH storage
station.
►
Turn in the sensors until they emit a signal.
►
Fasten the sensors at this position.
►
Coat the sensors with sealing lacquer.
6.1.3 Adjust the sensors in the storage
position
►
Position an MATCH gripper in the MATCH
storage station.
►
Turn in the sensors until they emit a signal.
►
Coat the sensors with sealing lacquer.
9
Sensor in storage position (MATCH
gripper present)
bl
Sensor in inspection position (test
channel, locking extended)
INSTALLATION AND OPERATING INSTRUCTIONS:
LWR50L-27
DDOC01645 / -
EN / 2022-08-08
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
Содержание MATCH LWR50L-27 Series