10. Troubleshooting
Error code
Error
Possible cause
Measure
0x0
No error
-
-
0x100
Actuator power supply is not pre-
sent or too low.
• Actuator power supply not
connected
• Cable break
•
Actuator power supply insuffi
-
cient
►
Check the actuator power
supply
0x101
Max. permitted temperature excee-
ded.
• Surrounding temperature too
high
• Overload of the gripper
►Ensure sufficient ventilation/
cooling/connection
0x102
Temperature below minimum per-
mitted temperature.
• Ambient temperature is too low
►Ensure sufficient operating
temperature
0x300
The configured "ControlWord" is
implausible.
• Multiple bits are set in the "Cont-
rolWord."
►
Only one bit is permitted to be
active in the “ControlWord”
0x301
The configured “TeachPosition” is
outside the permitted range.
• Wrong value on the "TeachPosi-
tion"
►
Test of the “TeachPosition”
parameters
►
Permissible range, depending
on model
►
Maximum position value corre-
sponds to the jaw stroke x 200,
e.g.: GEP2016 with approx.16.1
mm jaw stroke: 0 ≤ "TeachPositi
-
on" ≤ 3220
0x302
The configured gripping force is
outside the permitted range.
• Wrong value in the "GripForce"
parameter
►
Test of the “GripForce” parame-
ters
►
Permitted range: 0 < "Grip-
Force" ≤ 4
0x304
The configured tolerance value is
outside the permitted range.
• Wrong value in the "PositionTole-
rance" parameter
►
Test of the “PositionTolerance”
parameters
►
Permitted range: 0 < "Positi-
onTolerance" ≤ 255
0x305
The device has an incorrect refe-
rence position.
• Gripper does not have any refe-
rence position
►
►
Zimmer Customer Service
0x306
The configured "DeviceMode" is
implausible.
• Wrong value in the "DeviceMo-
de" parameter
►
Adjusting the “DeviceMode”
• Universal = 100
• Grip workpiece outside = 60
• Grip workpiece inside = 70
0x307
Movement order cannot be execu-
ted.
• Multiple move commands in the
same direction
• Move command transferred
despite existing error
►Reset the direction flag and
resend the move command
0x308
"WorkpieceNo" not available.
• Transmitted workpiece number
is outside the permitted range 0
to 32
►
Check the values of the "Work-
pieceNo" parameter
►
Apply the process data via a
"Handshake"