10.3 Installing the sensors
10.3.1 

Adjusting the magnetic field sensors

NOTICE

 

Note that switching point shifts may occur if the sensors are exposed to an additional, external magnetic field.

INFORMATION

The sensors are available as accessories.

 

More information can be found in the installation and operating instructions of the sensor.

10.3.2 Setting the inductive sensors
INFORMATION

External limit stops are a requirement to use inductive sensors.

 

For information on optional accessories and those included in the scope of delivery, refer to our website.

 

Switch off the power supply.

1
2
3

 

Slide the sensor into the terminal block.

 

Position the sensor at an appropriate switching distance from the 

switch cam.

 

Clamp the sensor.

1

Switch cam

2

Inductive sensor

3

Terminal block

10.4 Installing accessories

NOTICE

 

Before installing an accessory, make sure it is suitable for use with the selected variant.

 

You can find information on our website.

 

Please contact Zimmer Customer Service if you have any questions.

INSTALLATION AND OPERATION INSTRUCTIONS: 

GH6000

DDOC00274 / e

EN / 2023-02-13

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

Содержание GH6000

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS 2 jaw parallel gripper with long stroke pneumatic GH6000 DDOC00274 THE KNOW HOW FACTORY www zimmer group com...

Страница 2: ......

Страница 3: ...torage preservation 6 10 Installation 7 10 1 Installing the product 8 10 2 Installing the energy supply 8 10 3 Installing the sensors 9 10 3 1 Adjusting the magnetic field sensors 9 10 3 2 Setting the...

Страница 4: ...ding these dangers The warning symbols are assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can...

Страница 5: ...ried out on the product make sure that the product cannot be actuated by mistake Perform maintenance tasks renovation work or attachment work outside of the machine s danger zone when possible Do not...

Страница 6: ...ranteed Zimmer GmbH accessories are specifically tailored to the individual products For optional accessories and those included in the scope of delivery refer to our website 9 Transportation storage...

Страница 7: ...present NOTICE Installation may only be carried out by qualified personnel in accordance with these installation and operating instructions Switch off the power supply before any assembly installatio...

Страница 8: ...of delivery refer to our website 10 2 Installing the energy supply NOTICE You can find the information in the technical data sheet on our website Close off unused connections using pressure resistant...

Страница 9: ...essories and those included in the scope of delivery refer to our website Switch off the power supply 1 2 3 Slide the sensor into the terminal block Position the sensor at an appropriate switching dis...

Страница 10: ...free operation of the product can be reduced under the following circumstances Operation with impermissible compressed air Dirty environment Improper use and use that does not comply with the power s...

Страница 11: ...e specific technical documents were produced in accordance with Annex VII Part B of this Directive We undertake to provide the market supervisory bodies with electronic versions of special documents f...

Отзывы: