Index
Name
Data
format
Access rights
Values
Description
0x0017
(23)
Firmware version
STRING
Read
-
Firmware version
• Example: SWA000170_A00
• Type: SWA000170
• Version: A00
0x0040
(64)
Status
UINT16
Read
0 ... 65535
Reflection of the process data
0x0041
(65)
Diagnosis
UINT16
Read
0 ... 65535
Reflection of the process data
0x0042
(66)
Cycle counter
UINT32
Read
0 ...
4294967295
Current numbers of cycles
0x0043
(67)
Temperature
UINT16
Read
0 ... 100 °C
Current temperature
0x0044
(68)
ControlWord
UINT16
Read
0 ... 65535
Reflection of the process data
0x0045
(69)
Error code
STRING
Read
1 ... 32
Current error code
0x0046
(70)
Error counter
UINT32
Read
0 ...
4294967295
Current error counter
0x0100
(256)
Actual position
UINT16
Read
0 to max.
jaw stroke
of the
product
Reflection of the process data
0x0101
(257)
TeachPosition
UINT16
Read
0 to max.
jaw stroke
of the
product
Reflection of the process data
0x0102
(258)
WorkpieceNo
UINT8
Read
0 ... 32
Reflection of the process data
0x0103
(259)
DeviceMode
UINT8
Read
1 ... 95
Reflection of the process data
0x0104
(260)
PositionTolerance UINT8
Read
0 ... 255
Reflection of the process data
0x0105
(261)
GripForce
UINT8
Read
1 ... 130 %
Reflection of the process data
0x0107
(263)
DriveVelocity
UINT8
Read
1 ... 100 %
Reflection of the process data
0x0108
(264)
BasePosition
UINT16
Read
0 to max.
jaw stroke
of the
product
Reflection of the process data
0x0109
(265)
ShiftPosition
UINT16
Read
0 to max.
jaw stroke
of the
product
Reflection of the process data
16 Table with acyclic data (ISDU)
INFORMATION
IO-Link distinguishes between cyclical process data (PDU) and acyclic data (ISDU).
Access to acyclic data is not arranged very conveniently for all control system and IO-Link master combinations.
For this reason, the product can be used without acyclic data. This makes it as easy as possible to control the
product.
►
Please contact Zimmer Customer Service if you have any questions.
INSTALLATION AND OPERATING INSTRUCTIONS:
GEP2000
DDOC01113 / c
EN / 2022-11-16
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com