background image

ZIKA

 

 

OWNER'S    MANUAL 

 

I-PLAS 25/40 

         

                           

 
 
 
 
 

 

 

 

 

Содержание I-PLAS 25

Страница 1: ...ZIKA OWNER S MANUAL I PLAS 25 40...

Страница 2: ...cription 3 4 Technical parameters table 4 5 Installation instruction 5 6 Operation instruction 7 7 Panel instruction 8 8 Notes or preventive measures 10 9 Questions to be run into during welding 11 10...

Страница 3: ...ors should be used to avoid breathing gases Arc rays Harmful to your eyes burn your skin Wear suitable protective mask light filter and protective garment to protect eyes and body Prepare suitable pro...

Страница 4: ...ly by the quickly flowing air and the temperature can be up to 10000 15000 centigrade degree That forms the electrolyte estate and then form strong plasma arc It has the functions of arc initiation cu...

Страница 5: ...ltage V 269 268 Current Range A 20 80 20 100 Rate output voltage V 112 120 Duty cycle 60 60 Efficiency 85 85 Power factor 0 93 0 93 Insulation Class F F Housing Protection Class IP21 IP21 Arcing Way U...

Страница 6: ...MANUAL 5 I PLAS25 40 Front Panel Instruction of I PLAS25 1 Current meter 2 Abnormal indicator 3 Current selection knob 4 Positive output terminal 5 Negative output terminal 6 Torch switch socket 7 Pi...

Страница 7: ...PANEL FUNCTION INSTRUCTION Front Panel Instruction of I PLAS40 1 Power switch 2 Current selection knob 3 Abnormal indicator 4 Current meter 5 Negative output terminal 6 Torch switch socket 7 Pilot ar...

Страница 8: ...essure resisting air pipe to connect the air intake and compressed air source tight the joint with hoop or other ways in case of gas leaking Dry gas with suitable pressure and flow should be supplied...

Страница 9: ...on the air valve turn up the pressure adjusting knob Turn the pressure to rated value meter inside shows Kgf cm 2 and then put down the knob means increasing pressure _ means decreasing pressure 6 Sca...

Страница 10: ...working area is adequately ventilated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to watch the max duty current Response to the...

Страница 11: ...tage is low and input cable is too long C Output current is not up to the rated value When power voltage departs from the rated value it will make the output current not matched with rated value when...

Страница 12: ...tly 4 Avoid water and steam enter into inter machine if they enter into machine please dry inter machine then check insulation of machine 5 If welding machine will not be operated long time it must be...

Страница 13: ...and there is no DC 24V output Switch indicator is lit and fan is working However press control knob of torch there is no HF arc striking sound and inner red diode is lit 1 Check if MOS K34207 of top...

Страница 14: ...broken 3 Control circuit is broken Contact factory Abnormal indicator is lit meter is normal fan is normal 1 High pressure device is broken 2 IGBT is broken 3 Rectifier broken 4 Control board is brok...

Отзывы: