QS-002-0002-000-00 | December 18, 2020 

 

OUTPUT Select Button 

Pressing the Output button will toggle between blue 
and red illumination.  If the OUTPUT button is blue, 
then  Output  #1  will  be  connected  to  the  selected 
HDMI input.  If the OUTPUT button is red, then Output 
#2 will be connected to the selected HDMI input. 
 

Example: Connect HDMI In #3 to HDMI Out #1 

a.

 

Press Output until blue illumination. 

b.

 

Press HDMI 3, this button will illuminate blue. 

 

Example: Connect HDMI In #4 to HDMI Out #2 

a.

 

Press Output until red illumination. 

b.

 

Press HDMI 4, this button will illuminate red. 

 

POWER Button 

Pressing this illuminated button will toggle between 
Active Mode (Blue) and Stand-By Mode (Red).  In low 
power Stand-By Mode, no video will be present at the 
output and the audio will be muted.  
 

HDMI Inputs 

Connect the  video sources  to any of the  four HDMI 
inputs,  which  corresponds  to  the  HDMI  Selection 
buttons 1-4 located in the  front.  Input #1 supports 
ARC. 
 

HDMI Outputs 

Connect  a  display  or  AVR  to  the  HDMI  Scalable 
Outputs.  One of the selected inputs will route video 
and embedded audio to the output.  ARC is supported 
from Output #1.  
 

SPDIF (TOSLINK) Outputs 

The  SPDIF  (TOSLINK)  optical  port  will  output  audio 
from the selected HDMI In or ARC from HDMI Output 
#1. 
 

Analog Audio Outputs 

The  Analog  Audio  Left/Right  Outputs  can  be 
configured for Balanced or Unbalanced 

(refer to the 

SW-42Plus User Manual for proper wiring diagram)

.  

The  analog audio  can be  sourced  from  the  selected 
HDMI  In  or  ARC  from  HDMI  Output  #1.    Only  2-
Channel Stereo format is supported. 
 

RS-232 Port 

The RS-232 port is typically connected to a 3

rd

 party 

Control System to configure 
the SW-42Plus.  The default 
settings are:  

Baud Rate: 115,200 
Data Bits: 8 | Stop Bits: 1 
Parity: None | Flow Control: None 

 
Refer to the SW-42Plus User Manual for a complete 
description of the RS-232 control protocol. 

 

IR Input Connection 

The IR Input port can be connected to an IR Receiver 
(3-pin  Plug,  5V)  or 
any 3

rd

 party Control 

System  (2-pin  Plug).  
The  pin  out  for  the 
IR connectors are as 
follows: 

 

Ethernet LAN Port 

The Ethernet LAN port is a 100 Base-T connection to 
any  router,  network  switch,  computer,  or  3

rd

  party 

Control  System  (driver  required).    The  SW-42Plus 
features  a  Web  Graphical  Interface,  called  ZigNet.  
Any computer with a web browser can access ZigNet 
to  configure  the  device,  manage  EDID,  and  view 
advanced  diagnostics.   

Refer  to  the SW-42Plus  User 

Manual for more information on using ZigNet. 

 

Power 

The  SW-42Plus  requires  12VDC  @  2Amps  to  power 
the unit.  Use the included power adaptor and ensure 
the  locking  ring  is  threaded  snugly  to  prevent 
inadvertent disconnection of the power jack.    Make 
sure all video, audio, and control ports are properly 
connected before applying power to the SW-42Plus. 

 

GND (5) 

TX (2) 

RX (3) 

IR INPUT (2 or 3 pin support) 

IR In 

+5VDC 

GND 

IR In 

GND 

10 

11 