5 of 39 

  

SW-41Plus 4x1 HDMI Switch User Manual 
UM-002-0001-000-00 | 

July 22, 2020

 

© 2020 Zigen Corporation 

www.zigencorp.com 

S

W

-4

1P

lu

U

se

M

a

n

ua

Video Connection 

HDMI 2.0b 

Content Protection 

HDCP 1.4 | 2.2 

Maximum Video Resolution 

4K60P UHD 4:4:4, 4K60P UHD 4:2:2 HDR 

HDMI Inputs 

4x 

HDMI Outputs 

1x 

SPDIF Output 

1x 

Analog RCA Output 

Left/Right 

RJ-45 Ethernet LAN Port 

1x (10/100BaseT) 

RS-232 Port 

1x (DB9) 

3.5mm IR In Port 

1x 

IR Sensor (for Remote Control) 

1x 

2-Pin Power Input Jack 

1x (Locking Connector) 

Maximum HDMI Bandwidth 

17.82 Gbps 

Color Space Support 

RGB, YUV 

YUV Subsampling 

4:4:4, 4:2:2, 4:2:0 

Full Color Depth 

8 bits, 10 bits, 12 bits 

High Dynamic Range (HDR) 

Dolby Vision | HDR10+ | HDR10 | HLG 

Audio Format (HDMI Output) 

7.1 Channel PCM, DTS, DTS-HD, Dolby Digital, Dolby TrueHD, Dolby Atmos 

Audio Format (SPDIF Output) 

PCM, Dolby Digital, DTS 5.1 

Audio Format (RCA Output) 

2-Channel Stereo 

Audio DSP (RCA Output) 

Volume Attenuation, Tone Control Bass/Treble, 5-Band Equalizer, 

Equalizer Presets, Surround Sound Effects, and Bass Enhancement  

Auto Switching 

 

IR Remote Control 

 

RS-232 Port 

 

IR Input Port (2 or 3 Pins) 

 

Ethernet Port 

 

ZigNet Settings 

 

EDID Management 

 

Advanced Diagnostics 

 

CEC 

 

ARC (HDMI Input #1) 

 

Low Power Standby Mode 

 

Power 

12VDC @ 1A, Center pin hot 

Dimensions 

273.08mm x 21.84mm x 93.98mm | 10.75 inches x 0.86 inches x 3.7 

inches 

Weight 

635 grams | 1.4 pounds 

Temperature 

0° to 40° C (10% - 90% Non-Condensing Humidity) | 32° to 104° F 

HDMI 4K 600Mhz ESD Protection  Exceeds IEC61000-4-2 (Level 4) 
Contact/Air Gap Discharge on 

External Lines 

±15-kV 

Regulatory Safety and Emissions 

CE | FCC | RoHS | UL Listed Power Supply 

 

 

Specifications 

Содержание SW-41Plus

Страница 1: ...SW 41Plus MKIII 2020 4x1 HDMI 2 0 Switch User Manual SW 41Plus 4x1 HDMI Switch User Manual UM 002 0001 000 00 July 22 2020...

Страница 2: ...ear heat sources such as fireplaces heaters boilers radiators or any apparatus that produce heat such as computers or power amplifiers 5 Unplug equipment from power supply during dangerous lightning c...

Страница 3: ...sclaimer in the documentation and or other materials provided with the distribution 3 The name of the author may not be used to endorse or promote products derived from this software without specific...

Страница 4: ...RS 232 Cable male DB9 to female DB9 2x Wall Mounting Ears including Hardware 2x Rack Mounting Ears 1 2 Rack Height 4x Plastic Cushions 1x Quick Start Guide If any of these products are not present up...

Страница 5: ...HDMI Output 7 1 Channel PCM DTS DTS HD Dolby Digital Dolby TrueHD Dolby Atmos Audio Format SPDIF Output PCM Dolby Digital DTS 5 1 Audio Format RCA Output 2 Channel Stereo Audio DSP RCA Output Volume...

Страница 6: ...Audio RCA Outputs 9 RS 232 Connection 9 IR Input Connection 10 Ethernet LAN Port 10 Power 10 3 IR Remote Control 11 On Off Button 11 Input Buttons 1 4 11 Battery Compartment 11 4 Installation 12 Video...

Страница 7: ...ection 23 Master Volume 23 Equalizer 23 Surround Sound Effect 23 Bass Enhancement 23 Diagnostics Tab 24 Settings Tab 26 Device Information 27 Network Settings 27 Firmware Settings 27 10 RS 232 29 Conf...

Страница 8: ...embedded audio will be routed The selected button will illuminate blue while all other input buttons will be off Flashing LED behaviors may occur for alert and diagnostic purposes Power Button Pressi...

Страница 9: ...om the display SmartTV Apps will be passed through to HDMI input 1 if an ARC capable Audio Video Receiver AVR or Soundbar is connected SPDIF TOSLINK Output This SPDIF TOSLINK optical port will output...

Страница 10: ...LAN port is a 100 Base T connection to any router switch or directly to a computer The SW 41Plus features a web interface called ZigNet Hardware configuration EDID management and advanced diagnostics...

Страница 11: ...n Off Button Press these buttons to toggle between the operating modes OFF will set the unit in low power Stand By mode ON will set the unit in Active Mode and resets the unit Input Buttons 1 4 Press...

Страница 12: ...eceptacle on the rear panel of the switch 4 Connect the power supply to an electrical outlet IMPORTANT Ensure that all video audio and control port interconnects are properly connected before applying...

Страница 13: ...3 of 39 SW 41Plus 4x1 HDMI Switch User Manual UM 002 0001 000 00 July 22 2020 2020 Zigen Corporation www zigencorp com SW 41Plus User Manual 6 Interconnect Diagram Example Interconnect Diagram Example...

Страница 14: ...st time Input 1 will automatically be selected 2 Under normal conditions the four input selector buttons will illuminate blue when the corresponding input is selected However all input selectors will...

Страница 15: ...dicators which are associated with each HDMI input on the switch 1 When the SW 41Plus is powered on for the first time Input 1 will automatically be selected 2 Point the IR remote control unit at the...

Страница 16: ...sed Graphical User Interface GUI for control and management of the device To access ZigNet the SW 41Plus must be connected to the same network LAN as a computer with a web browser There are two networ...

Страница 17: ...our computer s Operating System such as Windows OSX or Linux Install ZigNet Locator then run the application Click the SEARCH button to find any network connected Zigen devices Find the proper SW 41Pl...

Страница 18: ...ack panel of the unit With ZigNet you are in full control Managing all of the excellent features our Zigen products have to offer is just a click away with a built in and free web interface Use the pr...

Страница 19: ...d tab Video Tab Allows the user to switch the inputs for the output and manage EDID settings Audio Tab Allows the user to manage audio settings Diagnostics Tab Allows the user to monitor video signals...

Страница 20: ...r Manual UM 002 0001 000 00 July 22 2020 2020 Zigen Corporation www zigencorp com SW 41Plus User Manual Video Tab Switching Source Click the desired HDMI input source to connect to the output The conn...

Страница 21: ...o the output EDID Management EDID Extended Display Identification Data informs the source what the sink is capable of receiving Manage the EDID that the sources receive by first selecting the desired...

Страница 22: ...22 of 39 SW 41Plus 4x1 HDMI Switch User Manual UM 002 0001 000 00 July 22 2020 2020 Zigen Corporation www zigencorp com SW 41Plus User Manual Audio Tab Audio...

Страница 23: ...frequency response of the Analog Audio output TOSLINK and Embedded audio of the HDMI output will not change 1 Presets Select a preset to configure the parametric equalizer 2 Graphical EQ Use the slid...

Страница 24: ...24 of 39 SW 41Plus 4x1 HDMI Switch User Manual UM 002 0001 000 00 July 22 2020 2020 Zigen Corporation www zigencorp com SW 41Plus User Manual Diagnostics Tab Diagnostics...

Страница 25: ...ce Input HDCP Status Indicates the HDCP authentication status of the selected input Output HDCP Status Indicates the HDCP authentication status of the output Resolution Indicates the video resolution...

Страница 26: ...26 of 39 SW 41Plus 4x1 HDMI Switch User Manual UM 002 0001 000 00 July 22 2020 2020 Zigen Corporation www zigencorp com SW 41Plus User Manual Settings Tab ZigNet Settings...

Страница 27: ...y and IP Mode Enter the IP Address Netmask and Gateway fields if IP Mode is set for Static If DHCP is selected then the network settings will be automatically configured by the DHCP Server If DHCP is...

Страница 28: ...lus User Manual Restart This feature restarts the unit Factory Reset Allows the unit to restore all settings back to factory defaults Note The SW 41Plus will revert back to default DHCP mode when rest...

Страница 29: ...ring an RS 232 Connection 1 Connect the RS 232 port on the back of the SW 41Plus to a computer using an RS 232 cable 2 Open a hyper terminal app of your choice Putty recommended on a computer 3 Enter...

Страница 30: ...ct name firmware release version build date serial number and network information Get IP address SW41 0001 getnet LF Displays the current IP address netmask and gateway if resolved Device Status SW41...

Страница 31: ...Corporation www zigencorp com SW 41Plus User Manual Note These commands can be combined like so SW41 xxxx st uptime version LF Device Command Examples To power ON the SW 41Plus use command SW41 xxxx...

Страница 32: ...tions and capabilities of a sink device to a source device HDCP High bandwidth Digital Content Protection is a form of digital copy protection to prevent copying of digital audio and video content acr...

Страница 33: ...gh Definition This is commonly referred to the video format 3840 x 2160 VESA Video Electronics Standards Association is a technical standards organization for computer display formats ZigNet Proprieta...

Страница 34: ...etwork HTTP or Curl protocol For specific usage details of the API download the API HTLM document from the Zigen Website in the SW41Plus downloads section 1 Get Active Source 2 Get Auto Switch 3 Get C...

Страница 35: ...0015 003f 0015 0015 0015 003f 0015 003f 0015 0015 0015 0015 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 0015 0015 003f 0015 003f 0015 003f 0015 1d0b Select Input 2 Description Set HDMI Outp...

Страница 36: ...cription Sets the unit in normal mode Command 0x18 Pronto Hex 0000 006e 0000 0022 0156 00ab 0015 003f 0015 0015 0015 0015 0015 003f 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015 003f 0015 003...

Страница 37: ...Command 0x45 Pronto Hex 0000 006C 0000 0022 0156 00ab 0015 003f 0015 0015 0015 0015 0015 003f 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015 003f 0015 003f 0015 0015 0015 003f 0015 003f 0015...

Страница 38: ...ation www zigencorp com SW 41Plus User Manual 14 Contacting Zigen Technical Support Tel 818 654 5252 Fax 818 654 5355 9 00AM 5 00PM PST Email info zigencorp com Web www zigencorp com Mailing Address Z...

Страница 39: ...specifications If at any time the product fails due to manufacturer defect Zigen will repair or replace the product to ensure that it meets original performance specifications Reduced performance due...