50
ProBee-ZS10 User Guide Rev.1.1
6.4
Security
AT+SECURITY=1<CR>
# set security level (ON)
OK
# Response
AT+LINKKEY=5A46
…
21<CR>
# set the 128-bit trust center link key (5A46
…
21)
ATZ<CR>
# Apply the change
OK
# Response
AT+NWKKEY=0<CR>
# set the 128-bit network key (random key)
OK
# Response
AT+UPDATEKEY<CR>
# update the changed network key
OK
# Response
6.5
Firmware Upload
6.5.1
Local N ode
# enter the bootloader menu for uploading firmware. Note that UART of local
node should be set to 115200-8-N-1-N.
AT+BOOTLOAD<CR>
Press Enter…
EM250 Bootloader v20 b09
1. upload ebl
2. run
3. ebl info
BL >
# press “1” and upload ebl file by X -modem
begin upload
CCCCCCCCCCCCC
Serial upload complete
# press “2” or reset after upload is done
6.5.2
Remote Node
# upload firmware to a remote node using 64-bit long address . Note that UART
of local node should be set to 115200-8-N-1-N.
AT+BOOTLOAD=1,00019500002FDC40<CR>
Please start .ebl upload image ...
CCCCCCCCCCCCC
# upload ebl file by X-modem
Bootload Complete!
# succeed to upload