40
ProBee-ZS10 User Guide Rev.1.1
that should join the same network. (0: Network specific, 1: ZigBee, 2: ZigBee Pro)
Execute
AT+STACK?<CR>
AT+STACK=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
0
Range
0 - 2
5.4.7
AT+NODENAME or AT+NN
Description
Get/Set the node name. It can be used to make a clear distinction role or functionality
of local node from others.
Execute
AT+NODENAME?<CR>
AT+NODENAME=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
ProBee-ZS
Range
Up to 16 characters
5.5
Network Formation and Join
5.5.1
AT+ASCAN or AT+AS
Description
Perform a scanning for existing network. It can take up to 5 seconds.
(CAUTION: It is possible to cause a link error if a node is a parent of an end-device.)
Execute
AT+ASCAN<CR>
AT+ASCAN=<channel mask><CR>
Response
<channel>|<PAN ID>|<EPID>|<joinable>|<stack profile>
List of the existing networks
…
OK<CR>
5.5.2
AT+ESCAN or AT+ES
Description
Perform a scanning for energy level of all channels. It can take up to 5 seconds.
(CAUTION: It is possible to cause a link error if a node is a parent of an end-device.)
Execute
AT+ESCAN<CR>
AT+ESCAN=<channel mask><CR>
Response
<channel>|<RSSI >
List of the RSSI for each channel
…
OK<CR>
5.5.3
AT+DSCAN or AT+DS
Description
Perform a scanning for existing nodes in the current network. A coordinator or router
can have children nodes and they are presented by “CLDn”. It can be possible to place
some conditions such as scan duration, node type and node name in order. The
information of local node is presented by “*”.
Execute
AT+DSCAN<CR> or