background image

20

Configure Network

4

Follow the wizard first to complete the thermostat setup based on your 
Heating system.

Searching gateway

Gateway connected

Let'sgetstarted.

START

The Thermostat will search gateway constantly when it is disconnected 

with gateway. So just simply set your gateway to permit joining (see 
your gateway's manual) and make sure the Thermostat is in the range of 
gateway's network, it will join the gateway automatically.

Quick reference to gateway connection icon

Connect to gateway

Содержание PCT512-Z

Страница 1: ...PCT512 Z ZigBee Touchsreen Thermostat EU Quick Start Guide 26 5 ...

Страница 2: ...sure to direct sunlight or strong ultraviolet light Do not drop or expose the unit to intense vibration Do not disassemble or try to repair the unit on your own Do not expose the unit or its accessories to flammable liquids gases or other explosives Do not use harsh chemicals or strong detergents to clean it Do not place it where infants and young children can touch children should use under paren...

Страница 3: ...ermostat or connect wirelessly to the boiler through receiver It will maintain the right temperature and hot water status to save energy when you at home or away This guide will provide you an overview of the product and will help you to use it 230V Combi boiler Dry contact Combi boiler System and heat only boilers Domestic hot water tanks Compatibility 26 5 ...

Страница 4: ...4 In the box 2 Power adapter 4 Drywall plugs 4 Screws USB Cable Pin Header User guide PCT512 Z ZigBee thermostat EU Quick Start Guide PCT512 Z Thermostat 26 5 Receiver Thermostat Stand Trim plate ...

Страница 5: ...hermostat Installation Guide 3 Breaker box Switch Warning High voltage The PCT512 thermostat must be installed and serviced only by a qualified electrical personnel Do not touch the terminals of the device during testing Make sure that the power supply is off before connecting or disconnecting it Always use a phase or voltage tester to confirm power is off Failure to follow these instructions will r...

Страница 6: ...hermostat before It is recommended that you install the thermostat wirelessly Otherwise please refer to the Wired installation chapter to install In this installation option the thermostat is powered by the adapter and controls your boiler wirelessly Thermostat Receiver Boiler 26 5 Wireless Installation ...

Страница 7: ...distance from any metal objects wiring pipes electrical grid wallboxes and boiler Please find a suitable position to install Receiver 30 cm Boiler Step 2 Wiring Refer to Chapter Receiver Wiring Page 14 to complete the wiring After that close the Receiver cover back and tighten the screw to secure the Receiver 1 2 ...

Страница 8: ...table position with a socket to mount You can mount the thermostat on the wall or using the stand included Once the best position has been identified remove the backplate from the Thermostat Insert the USB connector and clip the cable into the groove on the backplate to hold it in place 1 2 3 ...

Страница 9: ...mostat on desk shelf or other flat surface and insert the USB cable to socket with adapter Wall mount Mount the backplate to the wall using screws and plugs provided Use the Trim Plate behind it hide hole if needed After that gently press back the thermostat to its backplate and insert the USB cable to socket with adapter ...

Страница 10: ...10 Breaker box Switch Step 4 Power on your system Congratulation The installation is finished Please power on your system ...

Страница 11: ...It is recommended that you install the thermostat by wire The following is one of wired installation ways you can also refer to FAQ to install in other way Thermostat Boiler 26 5 In this installation option the Thermostat is powered and controls your boiler directly by using the existing wall wires ...

Страница 12: ...s installation you won t need them Keep them aside Step 2 Wiring Refer to Chapter Receiver Wiring Page 14 to complete the wiring Step 3 Installing thermostat Combination After the wiring is completed fix the front panel of thermostat to the backplate of Receiver through Pin Header included 2 2 1 1 ...

Страница 13: ...13 Breaker box Switch Step 4 Power on your system Congratulation The installation is finished Please power on your system ...

Страница 14: ...existing thermostat or receiver wiring from your boiler directly removing the cover of them and taking a picture of cable connections The same terminal name may represent different functions in different brands please refer to their manual to identify the cables of the corresponding terminals After that disconnect the wiring and remove your old thermostat receiver Boiler 1 2 N 1 2 3 4 L ...

Страница 15: ...l Receiver terminal designation Terminals What it means L Live wire N Neutral wire Earth wire 1 Hot water relay normally open 2 Hot water relay common 3 Hot water relay normally closed 4 Heating relay normally open 5 Heating relay common 6 Heating relay normally closed 12V 12V DC power output to Thermostat GND Ground on 12V DC L N 1 2 3 4 5 6 GND 12V ...

Страница 16: ... circuit connect it to 1 2 3 as needed Step 3 Mount the receiver Pass the cables through the Receiver from the bootom or rear and mount the backplate to the wall using screws and plugs provided Use the Trim Plate behind it to hide hole if needed Step 5 Installing thermostat After the wiring is completed close the terminal block flap back to Receiver and return to the previous installation chapter ...

Страница 17: ...ring diagrams The following is the wiring diagrams for different systems 230V combi boiler L N 1 2 3 4 5 6 GND 12V N L Boiler L N 3A fuse 230V 50Hz L N 1 2 3 4 5 6 GND 12V N L SL Boiler L N 3A fuse 230V 50Hz ...

Страница 18: ...18 L N 1 2 3 4 5 6 GND 12V A B Boiler L N 3A fuse 230V 50Hz L N 1 2 3 4 5 6 GND 12V N L RT RT Boiler L N 3A fuse 230V 50Hz Dry contact combi boiler ...

Страница 19: ... 4 5 6 GND 12V L N 3A fuse 230V 50Hz N L Boiler NO COM O GR BW O GR BW Heating valve Water valve Hot water tank Y plan L N 1 2 3 4 5 6 GND 12V L N 3A fuse 230V 50Hz N L Boiler NO COM O GR W Zone valve Hot water tank NC BL ...

Страница 20: ...et s get started START The Thermostat will search gateway constantly when it is disconnected with gateway So just simply set your gateway to permit joining see your gateway s manual and make sure the Thermostat is in the range of gateway s network it will join the gateway automatically Quick reference to gateway connection icon Connect to gateway ...

Страница 21: ...cancel the boost to follow schedule When receiver disconnected with Thermostat Press once to turn on heating manually until you press again to cancel it Hot water button When receiver connected with Thermostat Press once to turn on hot water for 1 hour manually or cancel the boost to follow schedule When receiver disconnected with Thermostat Press once to turn on hot water manually until you press...

Страница 22: ...lashing in green Searching Thermostat for 2 minutes Steady green light Connected with Thermostat Flashing in red No Thermostat is found stop searching Steady red light Disconnected with Thermostat Reset Hold heating button for 10 seconds until receiver s status light flashes red After reset the receiver will search Thermostat automatically Activate pairing Hold heating button for 5 seconds until r...

Страница 23: ...p Turn down Current day time Long press to change quickly Long press to change quickly THU 15 09 60 Follow Schedule HOME ON Hot water status Swipe left and right on the main screen to switch the display of heating and hot water You can tap the Hot water status to switch hot water ON OFF When the background turns red it means heating ...

Страница 24: ...ou select I change it it will hold the setpoint temperature permanently Reference to icons THU 15 09 60 26 5 26 5 HOME A specific duration I change it Next schedule Hold 26 5 Until Note Boost will override schedule and away setting You can click the cancel icon to get back to schedule or away setting Home Follow schedule setting to heating or switch hot water status You can tap this icon to switch ...

Страница 25: ... other days Start over Edit Schedule Heating Sa e Delete 5 5 End Time 0 00 Start Time 04 00 Schedule is a very important feature you can go to Menu Heating Hot water schedule to create your own schedule The daily schedule shows the target temperature for each time period You can tap the corresponding target temperature block to edit it Timeline Target temperature ...

Страница 26: ...nimum length of the schedule for each time period is 15 minutes so when you set the start end time the system will automatically correct your setting to avoid errors If you want to subdivide your schedule you can tap the icon in the upper right corner of the daily schedule to add a new schedule Select the time period you want to add a new schedule and tap the corresponding target temperature block...

Страница 27: ...lation ways Thermostat Receiver Boiler 26 5 The first installation is basically the same as the wireless installation the difference is that the location of the receiver is moved from near the boiler to the outside wall Boiler Receiver Thermostat 26 5 ...

Страница 28: ... is powered by the recever through the existing wall wires So you don t need to find an socket to power thermostat You can refer to the wireless installation After the wiring between your receiver and the boiler is completed you need to wire the 12V and GND terminal to the Thermostat accordingly 4 5 6 GND 12V GND USB 12V ...

Страница 29: ...ency 2 4GHz Internal PCB Antenna Range outdoor indoor 100m 30m Open area Radio 868Mhz Physical Specifications Display 4 inch Full color touch screen 480x480 Operating Voltage DC 5V DC 12V Operating Environment Temperature 20 C 50 C Humidity up to 90 non condensing Dimensions 104 L 104 W 21 H mm Mounting Type Wall mounting Stand Thermostat ...

Страница 30: ...30 Receiver Operating Voltage 100 240VAC Output 12V 1A Relay 10A Radio 868Mhz LED 2 color LED Red Green Dimension 109 L 109 W 28 H mm Mounting Type Wall mounting ...