STW20K 

12440-0702-03

 

Page

 

3 / 8 

www.ziehl.de 

  

 

General Notes 

 
Compliance with the following instructions is mandatory to ensure the functionality and safety of the 
product.  If  the  following  instructions  given  especially  but  not  limited  for  general  safety,  transport, 
storage, mounting, operating conditions, commissioning and disposal / recycling are not observed, 
the product may not operate safely and may cause a hazard to the life and limb of users and third 
parties.  
 
Deviations  from  the  following  requirements  may  therefore  lead  both  to  the  loss  of  the  statutory 
material defect liability rights and to the liability of the buyer for the product that has become unsafe 
due to the deviation from the specifications. 
 

 
 

Display and controls 

 

 
 

 
 
 
1. LED green Power On 
 
2. LED red Alarm 
 
 
 
 
 
 

Application and short description 

The current relay STW20K monitors the current in up to 3 lines with current transformers STWA1 (AND 
circuit). If there is a current in all 3 monitored lines, the relay (2 change-over contacts) picks up. If there is no 
current in at least one of the lines, the relay releases. The relay works in closed circuit current. When voltage 
is applied to the STW, the relay signals an alarm until the it has picked up. 
Identifies power failure with 1- or 3-phase electrical consumers, e.g. with monitoring of heating elements or 
heating installations where a constant heating has to be guaranteed. 
A further application is the identification of phase failure, monitoring of fuses, or triggering of operating hours 
counters. 
If the switching threshold is not reached due to low currents of less than 1 A, the monitored wire should be led 
multiple times through the transformer STWA1, STWA1H. Not required inputs have to be connected to a 
occupied input. 
 

Overview of functions 

 

3 current transformers STWA1 

 

AND-evaluation 

 

relay output 2 CO 

 

Switching point approx. AC 1 A 

 

LED-display for power on and alarm 

 

housing design K 

 

 

Содержание STW20K

Страница 1: ...w ziehl de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN Switching Relays and Controls Measuring Transducers Grid and Plant Protection Operating Manual STW20K updated 2019 07 31 Fu STW20K 12440 0702 03 Page 1 8 www ziehl de Current Relay for AC Detection AND Evaluation 3 Transformers ...

Страница 2: ...2 Display and controls 3 3 Application and short description 3 4 Overview of functions 3 5 Connecting diagram 4 6 Important Information 4 7 Installation 5 8 Commissioning 5 9 Detailed description 6 9 1 Tips 6 10 Disposal 6 11 Error search 6 12 Technical data 7 13 Housing Type K 8 ...

Страница 3: ...ent in up to 3 lines with current transformers STWA1 AND circuit If there is a current in all 3 monitored lines the relay 2 change over contacts picks up If there is no current in at least one of the lines the relay releases The relay works in closed circuit current When voltage is applied to the STW the relay signals an alarm until the it has picked up Identifies power failure with 1 or 3 phase e...

Страница 4: ...d the relevant security instructions for the setting up and the use of electrical units The equipment is built according to EN and checked and leave the plant according to security in perfect condition If in any case the information in the instructions manual is not sufficient please contact our company or the responsible representative To maintain this condition you must observe the safety instru...

Страница 5: ...se twisted or shielded cables Attention The polarity of the current transformer output white marking on the cable must be observed only if several current transformers are connected in series to increase the sensitivity 7 Installation mount on 35 mm mounting rail according to EN 60715 wall mount with 3 x screws M4 connecting wires refer to the connection plan to prevent miss operation and malfunct...

Страница 6: ...t too high current in wire too low Loop through wire several times Limit too low small loads shall not be recognized Connect a resistor 0 25 W 200 V in parallel to the current transformer STWA1 H resistor 750 Ohm enhancement by factor 2x resistor 330 Ohm enhancement by factor 4x resistor 150 Ohm enhancement by factor 10x Because of high tolerances we recommend to determine the best value by try ou...

Страница 7: ...current AC 15 Ie 3 A Ue 250 V Rated operational voltage DC 13 Ie 2 A Ue 24 V DC 13 Ie 0 4 A Ue 120 V Ie 0 2 A Ue 240 V Recommended fuse NO 4 A time lag or miniature circuit breaker MCB B4 Recommended fuse NC 3 15 A time lag Test conditions EN 61010 1 Rated impulse voltage 4000 V Overvoltage category III Pollution degree 2 Rated insulation voltage Ui 300 V On period 100 EMC tests EN 61326 1 industr...

Страница 8: ... AWG 22 14 Stranded wire with ferrules insulated ferrules 1 x 0 14 mm2 1 5 mm2 AWG 28 16 Stripping length Tightening Torque 8 mm 0 5 Nm Protection class housing terminals IP40 IP 20 Mounting Snap mounting on 35 mm standard rail EN60715 or M4 screws additional bar not included Mounting position any Weight app 120 g Subject to technical changes 13 Housing Type K 1 Bottom 2 Top 3 Bolt 4 Screw 5 Holes...

Отзывы: