MU100U
10730-0701-00
Page
7 / 8
www.ziehl.de
Test voltage
Input / output / power supply 2500 VAC
EMC-tests
Emission
EN 61000-6-2
Immunity
EN 61000-6-3
Installation conditions
Permissible ambient temperature
0 °C ... +50 °C
Permissible storage temperature
-
20 °C …+70 °C
Permissible wiring temperature
-5 °C
…+70 °C
Climatic conditions
5 … 85% rel. humidity, no condition
Installation height
< 2000 m over N.N.
Housing
Type K
Dimension (H x W x D)
75 x 22,5 x 110 mm
Width
1 TE
Line connection solid wire
1 x 0,5 mm
2
– 2,5 mm
2
/ AWG 22 - 14
Standard wire with insulated ferrules
1 x 0,14 mm
2
– 1,5 mm
2
/ AWG 28 - 16
Torque
0,5 Nm
Protection class housing / terminals
IP40 / IP 20
Mounting
Snap mounting on 35 mm standard rail EN60715 or
M4 screws (additional bar not included)
Mounting position
Various
Weight
app. 200 g
Subject to technical changes