Important Information 

 

DANGER!

 

 

Hazardous voltage! 

 

Will cause death or serious injury. Turn off and lock out all power  

 

supplying this device before working on this device. 

 

To use the equipment flawless and safe, transport and store properly, install and start professionally and 
operate as directed. 
Only let persons work with the equipment who are familiar with installation, start and use and who have 
appropriate qualification corresponding to their function. They must observe the contents of the instructions 
manual, the information which are written on the equipment and the relevant security instructions for the 
setting up and the use of electrical units. 
 
The equipments are built according to DIN / EN and checked and leave the plant according to security in 
perfect condition. If, in any case the information in the instructions manual is not sufficient, please contact 
our company or the responsible representative. 
Instead  of  the  industrial norms  and regulations written  in  this  instructions  manual  valid  for  Europe,  you 
must  observe  out  of  their  geographical  scope  the  valid  and  relevant  regulations  of  the  corresponding 
country. 

 

Observe the maximum temperature permissible when installing in switching cabinet. Make 
sure  sufficient  space  to  other  equipment  or  heat  sources.  If  the  cooling  becomes  more 
difficult  e.g.  through  close  proximity  of  apparatus  with  elevated  surface  temperature  or 
hindrance of the cooling air, the tolerable environmental temperature is diminishing. 

 

 

Attention! 

 

When all relays are programmed in operation current mode (= pick up at alarm), a loss of the 

supply voltage or an instrument failure can remain unidentified. When the relay is applied as control 
instrument,  the  operator  must  ensure,  that  this  error  is  recognized  by  regular  examinations.  We 
recommend  to  program  and  accordingly  evaluate  at  least  one  relay  in  the  closed-circuit  current 
mode. 

 

 
Universal power supply 

The device has got a universal power supply, that is suitable for DC- and AC-voltages. Before connecting 
the device to supply-voltage make sure that the connected voltage  corresponds with the voltage on the 
lateral type on the device. 

 

Installation 

The unit can be installed as follows: 

 

Installation in switchgear cabinet on 35 mm mounting rail according to EN 60715

 

 

With screws M4 for installation on walls or panel. (additional latch included in delivery) 
Connection according to connection plan or type plate. 

 

 

!

Содержание FRMU1000

Страница 1: ... relay state 5 Pushbutton up 2 Digital display 5 digits 6 Pushbutton set reset 3 LED speed measuring 1 min 7 Pushbutton down 4 LED frequency measuring Hz 2 Presetting 2 programs Pr can be selected Due to these Programs the device can be easily adapted to the application Choose the Program fitting to your application and after that change the parameters When changing the program all parameters are ...

Страница 2: ...Z00 H Hysterisis 10 1Z00 dAL Alarm delay 0Z50 0Z10 dof Switch back delay 0Z50 0Z10 rel Relais function r r Alarm 2 AL 2 K2 Limit 2 lower window limit 5000 47Z00 Fvnc Function k alHi upper window limit 53Z00 H Hysterisis 100 1Z00 dAL Alarm delay 0Z50 0Z10 dof Switch back delay 0Z50 0Z10 rel Relais function r r denab Start up delay 2Z0 0Z1 ddisp Display delay 0Z5 0Z5 ovt nur FRMU Type 0 10 0 10 ____...

Страница 3: ...d and relevant regulations of the corresponding country Observe the maximum temperature permissible when installing in switching cabinet Make sure sufficient space to other equipment or heat sources If the cooling becomes more difficult e g through close proximity of apparatus with elevated surface temperature or hindrance of the cooling air the tolerable environmental temperature is diminishing A...

Страница 4: ...d over frequency without reclosing lock overspeed over frequency with reclosing lock w_r underspeed under frequency without reclosing lock w__ underspeed under frequency with reclosing lock k window monitoring without reclosing lock window monitoring with reclosing lock alhi upper limit when monitoring a window H hysterisis dal switching delay doF switch back delay rEl function of relay r closed c...

Страница 5: ...Si o k Pi n Zero Fullscale Svm AL 2 Limit 00005 99999 f vnc of f w _r w __ k al H i 00005 99999 H 00001 10000 dAL 000 05 099 99 s doF 000 05 099 99 s r EL r A denab Value ddi sp Value 00000 99999 00000 09999 00001 00250 di v 00001 00250 m vl t Value Value Value Up Set Down Reset 2s Set 0000 0 0060 0 0000 1 0002 0 s s FRMU only Up down at same time sets values on zero Code reset 2 s set while switc...

Страница 6: ...c of f w _r w __ k al H i 010 00 500 00 H 000 10 010 00 dAL 000 05 099 99 s doF 000 05 099 99 s r EL r A 0000 0 0060 0 denab Value 0000 1 0002 0 ddi sp Value 010 00 500 00 00000 09999 Up Set Down Reset 2s Set s s FRMU only 6 3 Program 2 Pr2 Frequency Monitoring Operation with pushbuttons Up down on same time sets values on zero Code reset 2 s set while switching in Pin 00504 error messages Er 9 de...

Страница 7: ...40 V Tolerance DC 20 4 297 V AC 20 264 V Frequency 0 40 500 Hz from AC 80 V 10 500 Hz Input 3 W 10 VA Relay output 2 x 1 Changer CO Switching voltage max AC 400 V Switching current max 5 A Switching power max 1250 VA ohm resistive load max 48 W at DC 24 V Nominal operating current Ie AC 15 Ie 2 A Ue 250 V DC 13 Ie 2 A Ue 24 V Ie 0 2 A Ue 240 V Contact life mechanic 15 x 106 Switching cycles Contac...

Страница 8: ...e E1 E2 18 V 3 mA Switching threshold approx 9 V Analogue output FRMU only electrically insulated to input f in U1 U2 Voltage output 0 10 V max 10 mA error 0 1 of full scale Temperature factor 0 01 K Current output 0 4 20 mA max 500 Ω error 0 15 of full scale Temperature factor 0 015 K Error from burden 250 Ω resistance 250 Ω 0 15 of final value Nominal rise time 20ms messuring time Resolution ana...

Отзывы: