![ZIEHL-ABEGG ZA top SM200.40E Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/ziehl-abegg/za-top-sm200-40e/za-top-sm200-40e_original-operating-instructions_933579018.webp)
5.4.2
Connecting cable contact assignment
5.4.2.1
Absolute encoder ECN1313 EnDat/ECN1313 SSI
PIN
Function
Designation
Jumper
M16 x 0.75
(SV120)
Jumper
M23 x 1
Jumper
D-SUB
15 pole
A
14
1
DATA+
Data line for communication with the absolute encoder
B
17
2
DATA-
Data line inverse
C
1
3
Sensor Up Voltage supply sensor cable (positive)
D
7
4
Up
Voltage 5 V DC
E
10
5
0 V
Power supply ground
F
12
7
B+
Analog track B (sine)
G
9
9
CLOCK-
Clock signal invers
H
8
10
CLOCK+
Clock signal for serial transfer
J
4
11
Sensor 0 V Sensor cable for absolute encoder voltage (negative)
K
15
12
A+
Analog track A (cosine)
L
16
13
A-
Analog track A invers (cosine invers)
M
13
14
B-
Analog track B invers (sine invers)
Table 5-4-2-1
5.4.2.2
Absolute encoder AE-S64-BISSC-05-ZA
PIN
Function
Designation
Jumper
D-SUB
15 pole
1
DATA+
Data line for communication with the absolute encoder
2
DATA-
Data line inverse
3
-
-
4
VCC
Voltage 5 V DC
5
GND
Power supply ground
6
-
-
7
B+
Analog track B (sine)
8
-
-
9
CLOCK-
Clock signal invers
10
CLOCK+
Clock signal for serial transfer
11
-
-
12
A+
Analog track A (cosine)
13
A-
Analog track A invers (cosine invers)
14
B-
Analog track B invers (sine invers)
15
GND sense Power supply ground
Table 5-4-2-2
Translation of the original operating instructions
ZAtop
–
model series SM200.40E/SM200.45E
Electrical installation
A-TBA21_01-GB 2021/30 Index 003 Part.-No. 01013507-GB (EU-BD 1112)
18/64