ZIEHL-ABEGG PAE10E-M Скачать руководство пользователя страница 2

Operating Instructions PAE10E-M / PSE-6/14V  

 

 

Date 0618

 

R-TBL95_35_GB 0618   Part-No. 00158612-GB

 

 

- 2 - 

Contents 

1. General............................................................................................................................................. 3

 

2. Safety measures.............................................................................................................................. 3

 

3. General description ........................................................................................................................ 4

 

3.1 Range of application .........................................................................................................................................4

 

3.2 Technical data...................................................................................................................................................4

 

3.3 Versions ............................................................................................................................................................4

 

3.4 Controls.............................................................................................................................................................5

 

3.4.1 Manual speed setting or adjust of min. speed ( basic speed) .......................................................................5

 

3.4.2 Setting of max. speed-potentiometer (speed limiter) and cos 

ϕ

 adjustment .................................................5

 

4. Installation ....................................................................................................................................... 6

 

4.1 Mounting ...........................................................................................................................................................6

 

4.2 Minimum space requirement ............................................................................................................................6

 

4.3 Outdoor installation (PSE-6/14V or PAE10E-M in empty case IP 54)..............................................................6

 

4.4 Temperature influences during commissioning................................................................................................6

 

4.5 Systems with current-operated circuit-breaker.................................................................................................6

 

4.6 Potential of control voltage connections ..........................................................................................................6

 

4.7 Interference Emissions / Cable installation.......................................................................................................7

 

4.8 Electrical installation .........................................................................................................................................7

 

5. Basic settings / connections possible .......................................................................................... 8

 

5.1 Adjustment of the speed by an external potentiometer ....................................................................................8

 

5.2 Adjustment of the speed by an external signal.................................................................................................8

 

5.3 Voltage supply for external equipment .............................................................................................................8

 

5.4 Running several fans from one controller.........................................................................................................8

 

5.5 Stabilisation of the output voltage for fluctuations in the line voltage ...............................................................9

 

5.6 Output voltage 0-10 V.......................................................................................................................................9

 

6. Faults and their rectification .......................................................................................................... 9

 

6.1 Line faults..........................................................................................................................................................9

 

7. Enclosure....................................................................................................................................... 10

 

7.1 Connection diagram....................................................................................................................................... 10

 

7.2 Anschlussplan von Motorschutzgerät für Motoren mit Thermokontakten Typ S-ET10................................. 10

 

7.2 Dimension sheet ............................................................................................................................................ 11

 

Содержание PAE10E-M

Страница 1: ...V Part No 303585 Electronic speed controller for variable voltage 1 motors Manufacturer ZIEHL ABEGG AG Heinz Ziehl Stra e D 74653 K nzelsau Phone 49 0 7940 16 0 Fax 49 0 7940 16 200 Internet http www...

Страница 2: ...commissioning 6 4 5 Systems with current operated circuit breaker 6 4 6 Potential of control voltage connections 6 4 7 Interference Emissions Cable installation 7 4 8 Electrical installation 7 5 Basic...

Страница 3: ...ration If used in intensive animal environments any malfunctions in the air supply must be detected as soon as possible to prevent the development of a life threatening situation for the animals The d...

Страница 4: ...nsation Interference emission EN 61000 6 3 Harmonics current EN 61000 3 2 Interference immunity EN 61000 6 2 The units comply with EN 61000 3 2 for a professional unit Up to a maximum current of 4 amp...

Страница 5: ...x speed potentiometer speed limiter and cos adjustment Setting range from 100 down to setting n min This adjustment has to be made with full load condition i e when radial fans are used all dampers mu...

Страница 6: ...to the installation of several devices next to each other illustration When installing several devices on top of each other the danger of reciprocal heating exists This layout is only then permissible...

Страница 7: ...be longer than 30 m Screened control cables must be used when the cable length is longer than 20 m When using a screened cable the screen must be connected to the protective conductor at one end i e o...

Страница 8: ...nal circuit resistor 499 0 25 W between the terminals E and GND 5 3 Voltage supply for external equipment There is an integrated power supply for external equipment A selection between 15 V and 24 V i...

Страница 9: ...stabilisation must be switched off when loading the voltage supply for external units 15 V 24 V section 5 3 Voltage supply or for running from a mains transformer It is not meaningful to operate with...

Страница 10: ...upted KT00008G 15 07 2004 PE L N Netz oder geregelte Spannung line or controlled voltage Reseau ou tension variable Nat eller reglerad spanning 1 60V 250V 50 60Hz 1 2 4 6 12 11 24 23 Option ZB ZK 2S K...

Страница 11: ...s PAE10E M PSE 6 14V Date 0618 R TBL95_35_GB 0618 Part No 00158612 GB 11 Switch off the main supply before removing the cover Vor ffnen des Deckels Ger t spannungsfrei schalten 7 2 Dimension sheet PAE...