ZIEHL-ABEGG DN Series Скачать руководство пользователя страница 6

PTC on PTC triggering device.

Internally connected thermocontact: no external 
connection feasible or necessary. 

Caution:

 Ther-

most switches switch after triggering by excess 
temperature and closed independently after 
cooling off. The fan can start up during this time

Lead-out temperature monitors must be integrated in the 
control circuit in such a way that, if a fault occurs, 

the 

motor cannot switch on again automatically

 after it has 

cooled down. The protection of several motors using one 
protection device is possible by connecting the temper-
ature monitors of the individual motors in series. It must be 
remembered that if a temperature fault occurs at one 
motor, 

all

 motors will then be switched off. In practice, 

motors are therefore assembled in groups so that 

emer-

gency operation

 with reduced performance is still 

possible if a motor fails. 

Without thermal protection: Use a motor protection switch!

When in fan motors for 1~ 230V +/-10% the mains voltage is 
permanently over 240 V, in extreme cases the temperature 
monitor can trigger.In such cases a capacitor-type with the 
next smaller capacity should be used instead of the stated 
capacity."

Unit installation: Design GR..:

To avoid the transference of disruptive vibrations, we 
recommend de-coupling the entire plug fan to avoid 
sounds transmitted through solids. (Spring and/or attenua-
tion units are not a constituent part of the standard scope 
of delivery).  Look at our catalogue for positioning the 
decoupling elements or request a dimensions sheet stating 
the type designation and Part.-No.

Caution: All contact points must be 

xed securely to 

the base. If the 

xing is inadequate there is a risk of 

the fan overturning.

Erect in the open air only if this is expressly mentioned and 
con

rmed in the ordering information. There is a risk of 

damage to the bearings if the fan remains stopped in a 
moist environment. Avoid corrosion by suitable protective 
measures. Roo

ng is required. 

Making your own alterations/conversions on the fan 
module is unacceptable - safety risk.

In the case of a vertical motor axis, the respective lower 
condensation drain hole (if available) must be open.

Dahili olarak ba

ğ

lanm

ış

 termik 

ş

alter: Harici 

ba

ğ

lant

ı

 m

ü

mk

ü

n de

ğ

ildir veya gerekmemektedir. 

Dikkat:

 Termik 

ş

alterler y

ü

ksek s

ı

cakl

ı

nedeniyle att

ığı

nda, belli bir so

ğ

uman

ı

n ard

ı

ndan 

tekrar kendili

ğ

inden devreden ç

ı

kmaktad

ı

r. Bu 

s

ı

rada fan

ı

n çal

ış

maya ba

ş

lamas

ı

 m

ü

mk

ü

nd

ü

r

D

ış

ar

ı

 ç

ı

kart

ı

lm

ış

 olan termik röleler kontrol ak

ı

m

ı

 

devresine, bir ar

ı

za durumunda, so

ğ

uma gerçekle

ş

tikten 

sonra fan 

kendili

ğ

inden tekrar devreye girmeyecek

ş

ekilde ba

ğ

lanmal

ı

d

ı

r. Birden fazla motorun tek bir koruma 

cihaz

ı

 arac

ı

l

ığı

yla topluca korunmas

ı

 m

ü

mk

ü

nd

ü

r; bunun 

için motorlarda bulunan termik röleler seri olarak 
ba

ğ

lanmal

ı

d

ı

r. Bir motorda s

ı

cakl

ı

k nedeniyle bir ar

ı

za 

meydana geldi

ğ

inde 

t

ü

m

 motorlar

ı

n topluca devreden 

ç

ı

kart

ı

laca

ğı

n

ı

 dikkate al

ı

n. Bu nedenle gerçek 

uygulamada, bir motor ar

ı

zaland

ığı

nda d

üşü

k bir g

ü

çle 

acil i

ş

letim

 yapabilmek için motorlar gruplar halinde 

d

ü

zenlenmektedir.

Termik koruma olmadan: Motor koruma 

ş

alteri kullan

ı

n!

1~ 230V +/- %10 için olan fan motorlar

ı

nda 

ş

ebeke gerilimi 

s

ü

rekli olarak 240 V

un 

ü

zerinde bulundu

ğ

unda, termik 

rölenin atmas

ı

 m

ü

mk

ü

nd

ü

r. Bu durumda l

ü

tfen bir kademe 

daha d

üşü

k bir kondansatör kullan

ı

n.

Cihaz

ı

n kurulumu: GR.. yap

ı

 tipi:

Zararl

ı

 titre

ş

imlerin aktar

ı

lmas

ı

n

ı

 önlemek için plug fan

ı

tamam

ı

nda mekanik titre

ş

im sön

ü

mleyiciler kullan

ı

lmas

ı

 

önerilmektedir. (Yaylar veya sön

ü

mleme elemanlar

ı

 

standart teslimat kapsam

ı

na dahil de

ğ

ildir). Ba

ğ

la

şı

m

ı

 

kesme elemanlar

ı

n

ı

n konumland

ı

r

ı

lmas

ı

n

ı

, l

ü

tfen 

katalo

ğ

umuzdan ö

ğ

renin veya tip kodunu ve 

ü

r

ü

numaras

ı

n

ı

 belirterek bir ölç

ü

 sayfas

ı

 talep edin.

Dikkat: T

ü

m dayanak noktalar

ı

 i

ş

letim bak

ı

m

ı

nda 

emniyetli olacak 

ş

ekilde temele ba

ğ

lanm

ış

 olmal

ı

d

ı

r. 

Yeterli bir tespitleme yap

ı

lmad

ığı

nda fan için devrilme 

tehlikesi vard

ı

r.

ı

k alanlarda, ancak sipari

ş

 dok

ü

manlar

ı

nda sarahaten 

belirtilmi

ş

 ve onaylanm

ış

sa kullan

ı

labilir. Cihaz

ı

n uzun 

s

ü

re boyunca nemli ortamda çal

ış

madan beklemesi 

halinde yatak hasarlar

ı

 tehlikesi bulunmaktad

ı

r. Uygun 

koruyucu tedbirler alarak paslanmay

ı

 önleyin. Cihaz için 

bir koruyucu çat

ı

 gereklidir.

İş

letmecinin kendi inisiyati

 ile havaland

ı

rma mod

ü

l

ü

 

ü

zerinde de

ğ

i

ş

iklik/modi

kasyon yapmas

ı

na m

ü

saade 

edilmez 

 Emniyet riski.

Dikey motor aks

ı

nda, altta bulunan kondens suyu deli

ğ

(e

ğ

er varsa) aç

ı

lm

ış

 olmal

ı

d

ı

r.

6

T

ü

rkçe

english

00280351-GB-TR

L-BAL-005-TR-1939-Index 

014

Содержание DN Series

Страница 1: ...from the age of 14 up In the event of deviations further structural protective measures must be taken for safe opera tion Montaj talimatı Radyal ve diyagonal fanlar İçerik Bölüm Sayfa Kullanım 1 Emniyet Uyarıları 2 ErP Direktifine dair bilgi 3 Taşıma Depolama 4 Montaj 5 İşletim Koşulları 7 Devreye 8 Servis Bakım Temizlik 9 Tasfiye Geridönüşüm 10 Üretici 10 Servis adresi 10 Aşağıdaki kriterlere uyulm...

Страница 2: ...ced insulation nor by connection to safety earth in accordance with EN 60204 1 therefore the motor fan must be installed so that it is not touchable Emniyet Uyarıları Bu montaj talimatı ürünün bir parçasıdır ve her zaman kolayca ulaşılabilir bir şekilde saklanmalıdır Vantilatörler hava veya hava benzeri karışımların taşınması için tasarlanmıştır Patlama tehlikesi olan alanlarda gaz buhar sis veya ...

Страница 3: ... be found on www ziehl abegg de search key ErP ErP Direktifine dair bilgi ZIEHL ABEGG SE firması 2009 125 EG Direktifin yürütülmesine dair 30 Mart 2011 tarihinde komisyonun EU No 327 2011 sayılı tebliğ bundan sonra ErP tebliği diye anılacaktır uyarınca AB içinde belirli vantilatörlerin kullanım alanının belirli koşullara bağlı olduğuna işaret eder Yalnızca ErP tebliğinin gereklilikleri söz konusu van...

Страница 4: ... Koruyucu eldiven ve ayakkabı giyin Fanı fanları orijinal ambalajlarında veya daha büyük boyutlu fanları uygun taşıma araçları kullanarak öngörülen taşıma tertibatlarında gövde flanşı L tipi montaj braketi halkalı cıvataların vidalanması için motor gövdesinde delikler taşıyın GR yapı tipi Fan ünitesi sadece uygun bir kaldırma aracı Yük traversi kullanılarak kaldırılmalı ve taşınmalıdır Halatın veya...

Страница 5: ...ow Montaj Pervane vantilatör veya balans ağırlığını gevşetme Montajı ve elektrik bağlantısını yalnızca bırakın eğitimli uzman personel Koruyucu eldiven ve ayakkabı giyin Sisteme ilişkin montaj ve emniyet uyarılarının geçerli standartlar ve yönetmelikler DIN EN ISO 12100 13857 ile aynı doğrultuda olup olmaması tamamen sistemin veya tesisin üreticisinin sorumluluğundadır RE RH RM yapı tipine sahip f...

Страница 6: ...rain hole if available must be open Dahili olarak bağlanmış termik şalter Harici bağlantı mümkün değildir veya gerekmemektedir Dikkat Termik şalterler yüksek sıcaklık nedeniyle attığında belli bir soğumanın ardından tekrar kendiliğinden devreden çıkmaktadır Bu sırada fanın çalışmaya başlaması mümkündür Dışarı çıkartılmış olan termik röleler kontrol akımı devresine bir arıza durumunda soğuma gerçek...

Страница 7: ...arts İşletim Koşulları Ventilatoren patlayıcı ortamlarda işletilmemelidir Motorun fanın işletim türü DIN EN 60034 1 2011 02 uyarınca arada sırada çalıştırmalı S1 sürekli işletim 40 C ile 25 C arasında arada sırada çalıştırmaya izin verilir 25 C nin altında sürekli işletim sadece soğuk uygulamalar için talep üzerine sunulan özel yataklarla mümkündür İşletim için müsaade edilen minimum ve maksimum o...

Страница 8: ...o erratic operation unbalanced e g caused by transporta tion damage or improper use can lead to failure Devreye alınmasından önce kontrol edin Montaj ve elektrik tesisatı kurallara uygun olarak yapıldı mı Elektrik bağlantısı devre şeması uyarınca kuruldu terminal kutusunda devre şeması kablo veya duvar halkası kablo tipinde Dönüş yönü fan kanadı veya fan gövdesi üzerindeki dönüş yönü ok işareti il...

Страница 9: ...ntilator üzerinde tehlike bölgesinde yapılan tüm çalışmalarda şu hususlara dikkat edilmelidir Bu çalışmalar sadece bu konuda eğitim almış uzman personel tarafından yapılmalıdır Emniyet ve çalışma yönetmelikleri DIN EN 50 110 IEC 364 dikkate alınmalıdır Ventilator çalışır durumdayken bakım çalışması yapılmamalıdır Akım devresi kesilmiş ve tekrar çalıştırılmaya karşı emniyet altına alınmış Gerilim b...

Страница 10: ... the homepage at www ziehl abegg com for a list of our subsidiaries worldwide Tasfiye Geridönüşüm Tasfiye işlemi yasal düzenlemeler doğrultusunda tekniğe uygun ve doğaya zarar vermeden yerine getirilmelidir Üretici Ürünlerimiz uluslararası geçerliliğe sahip yönetmeliklere uygun olarak imal edilmiştir Ürünlerimizin kullanımına yönelik olarak sorularınız olduğunda veya özel uygulamalar planladığınızda...

Страница 11: ...eri Risk değerlendirmesi ve risk azaltma EN ISO 13857 2008 Makinelerde Güvenlik Kol ve Bacakların Ulaşabileceği Bölgelerde Tehlikenin Önlenmesi için Güvenlik Mesafeleri Uyarı EN ISO 13857 2008 standardına uyulması sadece teslimat kapsamına ait olduğu sürece monte edilmiş temas korumasına ilişkindir Ek VII B tarafından öngörülen özel teknik dokümanlar oluşturulmuştur ve eksiksiz mevcuttur Önemli te...

Страница 12: ...d risk reduction EN ISO 13857 2008 Safety of machinery safety distances to prevent danger zones being reached by the upper limbs Note The maintenance of the EN ISO 13857 2008 relates only to the installed accidental contact protection provided that it is part of the scope of delivery The specific technical documentation in accordance with Appendix VII B has been written and is available in its enti...

Отзывы: