Zibra corp ZC-LS006-1002 Скачать руководство пользователя страница 5

  

5  

 
2. HLS Features, Specifications & Accessories  

  

 

 

Light Source Features  

 
 
 

 

 

 Figure 1. Handheld Light Source Diagram 

 

Scope Adapter 
 

Specified at time of purchase, the 

Scope Adapter allows the Handheld Light Source to attach to the user’s 

endoscope.  Three configurations of the Zibra HLS are available:  
 

  UNIV:

  A Universal 

adapter that threads onto the standard light guide post’s Storz adapter thread.                                                                                                                                                                                                                             

Rotate the HLS clockwise to attach to an endoscope and counterclockwise to remove it. 

  ACMI:

  An adapter for the snap-in quick-connect ACMI light guide post. 

  WOLF: 

An adapter for the snap-in quick-connect Wolf light guide post. 

  

 

Power Module 
 

The battery can be removed and replaced for recharging.  Rotating the control to the 

Off

 position (0) will allow 

the Power Module to be pulled out. An o-ring seals the battery and electronics when the Power Module is 
inserted into the Heatsink/Handle. 

 

 

 

On/Off Switch: 

 

The 

On/Off

 switch turns the LED on/off 

at the “0” position.

 

 

Intensity Control Knob

:  

The knob will increase/decrease the light intensity of the HLS.

 

 

o

 

 Rotate the control towards the larger numbers of the intensity scale to turn the light source 
on and increase the light intensity.

 

o

 

Rotate the control to the zero end of the intensity scale to gradually decrease the light 
intensity and turn the light source off. Notice a click-in at both the 

off 

(0) and 

maximum

 (10) 

positions.

 

 

 

Battery Compartment:  

Remove and Replace battery.

  

o

 

See section 3 

– HLS Function and Operation for complete details.

 

 

 
 

 

Light Intensity 

  Indicator Dot 

  Scale 

 

Scope Adapter 

 UNIV 

 ACMI 

 WOLF 

Power Module 

  On/Off Switch 

  Intensity Control Knob 

  Battery Compartment 

 

  

Содержание ZC-LS006-1002

Страница 1: ...is covered under US Patents issued and pending Handheld LED Light Source HLS Operator s Manual Sales and Service by Zibra Corp 640 American Legion Hwy Westport MA 02790 USA USA Tel 1 800 758 8773 www...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...mended Separation Distance between Portable and Mobile RF Communications Equipment 14 7 Repair Service 14 8 Warranty 14 9 Symbol Descriptions 14 WARNING This device is not supplied sterile Clean and d...

Страница 4: ...oy this light source such as endoscopy WARNING Avoid direct viewing of the high intensity light at the front of the Handheld Light Source Never point it s light at other s This manual describes the pr...

Страница 5: ...the Off position 0 will allow the Power Module to be pulled out An o ring seals the battery and electronics when the Power Module is inserted into the Heatsink Handle On Off Switch The On Off switch t...

Страница 6: ...Operating Storage and Transport Relative Humidity Range 0 95 RH Battery Recharge Cycles 500 recharges RoHs Compliant Yes Accessories Light Sources Accessories Listing Part Number Handheld Light Source...

Страница 7: ...is finger tight Do not over tighten ACMI or Wolf Insert the light guide post of the endoscope into the Scope Adapter until it snaps into place It is normal for a small amount of play to exist between...

Страница 8: ...Power Module by carefully aligning the key on the bottom of the Battery Sled with the keyway cut in the Heatsink Handle NOTE The key must be aligned with the keyway before full insertion is possible P...

Страница 9: ...es the battery is fully charged or no battery is present 3 After the battery is fully charged pull the battery s out of the charger 4 Unplug the AC adapter when not in use to conserve energy CAUTION N...

Страница 10: ...le cleaning agent removes all types of debris or is safe to use with every type of reusable device Certain cleaning agents may damage the device s materials Cleaning agents should be used in the corre...

Страница 11: ...t as a result of rinsing with potable water 6 Dry the exterior of the light source with a soft clean towel III Drying the Light Source After the HLS becomes wet either from water or cleaning fluids th...

Страница 12: ...leared off Dry with compressed air or gas Light source becomes hot after prolonged use at full power Light source has been left on for more than 30 minutes at full power Turn the light source to a low...

Страница 13: ...n portable and mobile RF Communications Equipment and the HLS according to the maximum output power of the communications equipment Note The HLS is internally battery powered and has no I Os Conducted...

Страница 14: ...ny person not authorized by Zibra will result in immediate loss of warranty THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY...

Страница 15: ...____ _______________________________________ _______________________________________ _______________________________________ _______________________________________ ___________________________________...

Страница 16: ...16 Part No LS006 0057 Aug 2018...

Отзывы: