10
SNE2000G-P and SNE2000G-S
SNE2-A2-ZN13-10
NOTE: If the SHDSL connection loses link, the Ethernet connection will automatically be
disabled (as indicated by solid illumination of the Ethernet Rx, Tx and Lnk LEDs). Upon
reestablishment of at the SHDSL link, the Ethernet connection will be reinstated and the Ethernet
LEDs will reflect current Ethernet status.
Ethernet Tx
Flashing
Amber
Ethernet activity
The SNE2000G is transmitting data
across the Ethernet network.
Solid Amber Heavy Tx traffic
The SNE2000G is transmitting large
amounts of data across the Ethernet
network. A solid amber Ethernet Tx
LED can also signify a lost SHDSL
connection.
Ethernet Lnk
Solid Green
Ethernet connection
is established
A solid green Ethernet Lnk LED can
also signify a lost SHDSL connection.
No
Illumination
No Ethernet
connection
The Ethernet Rx and Tx LEDs will
remain unlit by default.
* A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks
at a more rapid, less constant rate.
Table 3:
LEDs (2 of 2)
LED
STATE
INDICATION
ADDITIONAL INFORMATION