A-10
IMACS System Release 5.1.9
Reference Guide
Model No.
Running Head
A.3.3.3
Airflow
Convection cooled (no fans required). Except for Model 891930 Power Enhanced Chassis.
A.3.3.4
Fire Resistance
As per GR-63-CORE Section 4.2.2.2 Shelf-Level Fire-Resistance Criteria R4-19 for
Firespread
R4-20,
Fire Propagation
R4-21, O4-22 and O4-23.
A.3.4
Equipment Handling
A.3.4.1
Packaged Equipment Shock Criteria
As per GR-63-CORE Section 4.3.1.1 for category A containers, R4-41.
A.3.4.2
Unpackaged Equipment Shock Criteria
As per GR-63-CORE Section 4.3.2 R4-43.
A.3.5
Earthquake, Office Vibration and Transportation Vibration
A.3.5.1
Earthquake
To Zone 4 Profile (Zone 4 is most severe so equipment also meets Zones 0, 1, 2, and 3 criteria).
Physical performance as per GR-63-CORE Section 4.4.1.2 R4-44. Functional performance as
per GR-63-CORE Section 4.4.1.2 R4-48 and R4-49.
A.3.5.2
Office Vibration
Physical performance as per GR-63-CORE Section 4.4.3.2 R4-56. Functional performance as
per GR-63-CORE Section 4.4.3.3 R4-57.
A.3.5.3
Transportation Vibration
Physical performance as per GR-63-CORE Section 4.4.4.1 R4-58.