background image

                                                                           

 

 

Please refer to the follow sheet for detailed pin information. 

Port Name   SN 

Name  

Note 

I/O Port  

ALARM_NO 

Alarm  output  port.  It  is  to  output  the  alarm  signal  to  the 
alarm device.  

NO: normal open alarm output port.  

It must be used with ALARM_COM. 

ALARM_COM 

Alarm output public port.  

ALARM_IN1 

Alarm input port 1. It is to receive the on-off signal from 
the external alarm source. 

4  

ALARM_IN2 

Alarm input port 2. It is to receive the on-off signal from 
the external alarm source. 

GND 

Ground port  

 

 

1.2

 

Framework and Dimension 

Please refer to the following figure for dimension information. The unit is mm. See Figure 1-2 and 

Figure 1-3. 

 

 

Figure 1-2 Dimension illustration 1 

 

Содержание DH-IPC-HFW5421E-Z

Страница 1: ...HD IR WDR Network Camera Quick Start Guide Version 1 0 1 Zhejiang Dahua Technology CO LTD ...

Страница 2: ...ock caused by improper handling or installation We are not liable for any problems caused by unauthorized modification or attempted repair 2 Transportation security Heavy stress violent vibration or water splash are not allowed during transportation storage and installation 3 Installation Do not apply power to the camera before completing installation Please install the proper power cut off device...

Страница 3: ...o clean the device Please put the dustproof cap to protect the CCD CMOS component when you do not use the camera Dome enclosure is the optical component do not touch the enclosure when you are installing the device or clean the enclosure when you are doing maintenance work Please use professional optical clean method to clean the enclosure Improper enclosure clean method such as use cloth may resu...

Страница 4: ... Cable 1 1 2 Framework and Dimension 2 2 Device Installation 4 3 Quick Configuration Tool 6 3 1 Overview 6 3 2 Operation 6 4 Web Operation 8 4 1 Network Connection 8 4 2 Login and Logout 8 Appendix Toxic or Hazardous Materials or Elements 10 ...

Страница 5: ... speaker and etc 2 AUDIO IN Audio input port RCA Input audio signal receive analog audio signal from pick up and etc 3 LAN Network port Ethernet port Connect to standard Ethernet cable 4 I O I O port Connect to I O port 5 Power Power input port Power port Input DC 12V or AC 24V power Standard DC 5 5 round port converts to 2 pin converter cable Please connect the DC5 5 round port to 2 pin converter...

Страница 6: ...h ALARM_COM 2 ALARM_COM Alarm output public port 3 ALARM_IN1 Alarm input port 1 It is to receive the on off signal from the external alarm source 4 ALARM_IN2 Alarm input port 2 It is to receive the on off signal from the external alarm source 5 GND Ground port 1 2 Framework and Dimension Please refer to the following figure for dimension information The unit is mm See Figure 1 2 and Figure 1 3 Fig...

Страница 7: ...3 Figure 1 3 Dimension illustration 2 ...

Страница 8: ...all the device wall or ceiling Step 2 Dig a hole according to position of hole on installation map Step 3 Open accessories bag take out expansion bolt and insert it into the hole you just dug Step 4 Open accessories bag take out screw Tighten the 4 screws to fix the device on the installation surface wall or ceiling You can move device sunshade back and forth When you have fixed the device you mus...

Страница 9: ...e installation 2 Step 6 Use wobbler driver in accessories bag to loosen adjusting screw Step 7 Adjust the device in all possible directions and set its monitoring direction Step 8 Use wobbler driver to tighten the screws ...

Страница 10: ...ion Double click the ConfigTools exe icon you can see an interface is shown as in Figure 3 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc Figure 3 1 Search interface Select one IP address and then right click mouse you can see an interface is shown as in Figure 3 2 Select the Open Device Web item you can go to the correspon...

Страница 11: ... user name password and port Please modify the corresponding information to login Please note the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you cannot login the device If you are using device background upgrade port 3800 to login other setups are all invalid Figure 3 3 Login prompt After you logged in the configuration tool ...

Страница 12: ... of the PC and the network camera respectively Network camera default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 Use order ping network camera address to check connection is OK or not 4 2 Login and Logout Open IE and input network camera address in the address bar See Figure 4 1 Figure 4 1 IP address The login interface is shown as below See Figure 4 2 Please i...

Страница 13: ...gin After you successfully logged in please install WEB plug in unit Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction See Figure 4 3 Figure 4 3 Web monitoring window ...

Страница 14: ...ll not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding local authorities to process according to your local government statutes Note This quick start guide is for reference onl...

Отзывы: