103
E—14 Memory parameter lost
The parameters stored in the memory are lost. Please check whether the
battery voltage of the main board is under DC2V. If so, please change batteries.
E—15 Memory design lost
The designs stored in the memory are lost. Please check whether the
battery voltage of the main board is under DC2V. If so, please change batteries.
E—16 No design in memory
There is no design in the memory. Please input designs with proper input
equipment.
E—17 No free design numbers
The system can have 99 memory design numbers at most. If more than 99
designs are input, no matter there is free space in the memory or not, the system
won’t permit the input of that new design.
E—18 Memory design number does not exist
The selected design number doesn’t exist in the memory. Before
embroidery, please check whether the selected design exists in the memory, or
enter the design review mode to select the design directly.
E—19 No enough memory space
Because of occupation by memory designs, the memory can’t provide
enough space for design input or design review.
E—50 Encoder abnormal
Encoder abnormal results in incorrect embroidery. Check the cable
Содержание BECS-129S