4.1
Initial inspection
Check that the gearbox is correctly installed
before taking it into operation.
Mechanical fastening
Motor flange-mounting
Gearbox oil ports and connections
Oil supply/oil fill assured
Electrical connections
Ease of movement (can be turned by hand)
Breather vertical position
5
Maintenance
5.1
Oil change
Oil change interval: Every 5000 operating hours
ENVIRONMENTAL
HAZARD!
Lubricants and cleaning agents must not
be allowed to enter the ground, the water
table or the sewage system.
• Request safety information for the
products concerned from your local
environmental protection authority and
follow any instructions herein at all
times.
• Always collect used oil in a suitably
large container.
• Always dispose of used oil, clogged
filters, lubricants and cleaning agents
in accordance with environmental
protection laws.
• Always observe manufacturer
instructions when dealing with
lubricants and cleaning agents.
Drain used gearbox oil into a suitable container if it
is at operating temperature.
The drain ports differ depending on the installation
position and gearbox version (see chap. 3.7.5).
Pour new gearbox oil through port E.
The oil level itself is all important. The oil quantity
in liters indicated on the model plate is a reference
value only.
If available, let the oil pump operate briefly after
filling with oil to remove any air and top up with oil
again if necessary.