b.Starter system test
In the main menu (Figure 3.1.0) Select option 2 (starter system testing), and
press <Enter> key to enter the starter system test interface (Figure 3.2.0 below).
prompted display interface to operate. After starting the engine to wait around
for about 15 seconds to read the test data (minimum voltage value). For 12V
systems. If the minimum voltage value is greater than 9.6V, then start the system
normally. If less than 9.6V, shows the battery voltage is too low to start, check
that the relevant part of the connection points, lines, and starters. If the 24V
system, the minimum voltage 19.2V places as a reference boundaries.
Test
result print operations can refer battery test results printing operation.
c.Charging System Test
In the main menu (Figure 3.1.0) Select option 3 (charging system test), press
<Enter> key to enter the charging system test, then the operation prompt
interface (Figure 3.3.0 below) will appear.