24
The Z10 series inverter is equipped with an integrated RCD (Residual Current
Protective Device) and RCM (Residual Current Operated Monitor). The current sensor
will detect the volume of the leakage current and compare it with the pre-set value, if the
leakage current exceeds the permitted range, the RCD will disconnect the inverter from
the AC load.
2. Assembly Instructions
1) Remove length y of
N, L
conductor 35mm (1.38’’)/
PE
conductor 40mm (1.57’’)
sheath of AC cable terminal, length x about 14mm (0.55’’) of the inner wrapper, then
dress the conductor terminals with ferrules or tin soldering.
Check that all parts of the AC connector are present then slide the hex nut onto the
cable and insert the cable end through the clamp ring.
NOTICE
Use
16-12AWG (1.5-4mm
2
)
copper wire for all AC
wiring connections to the Z10 series inverter. Use only
solid wire or stranded wire.