07
Appendix H: Viavi CX300 Tests
MAINTENANCE GUIDE | MT-4E ANALOG & P25 DIGITAL RADIO SYSTEMS
RECEIVER TESTING
Receiver Analog Testing
Connect the CX300 and Zetron Radio as shown in Figure H-3:
Figure H-3: Receiver Analog Testing
On the CX300, load Zetron preset 01 Rx Analog from your internal drive. Enter the correct RF frequency and
ensure that the deviation level of the 1.0 KHz tone is set correctly for your receiver (wide / narrow) in M1. Enter
the correct CTCSS tone (if used) and deviation level for the tone in M2. On the Zetron Radio system, ensure
the receiver is turned on and turn the System Regulator Speaker switch to ON and INT. Set the FUNCTION
rotary switch to position 3 for Rx A or position 5 for Rx B (depending on the receiver being tested), then turn the
volume up until the 1 KHz tone is audible.
Computer running RSS
USB from
Rx Balanced Audio Output
(from pins B26 and Z26)
Computer to Rx
RF OUTPUT from
CX300 to RF IN on Rx
AF INPUT 1
RECEIVER
SQ. DISABLE
OFF
NORM
BUS
CNTL
A D
RF I N
IN
REF
USB
FREQUENCY (MHz)
MADE IN CANADA
MODEL # CODE
VOL
SYSTEM REGULATOR
METER
+
-
MADE IN CANADA
ON
OFF
SPKR
INT
EXT
EXT
SPKR
OFF
POWER
ON
2
1
5
4
3
6
7
8
11
10
9
FUNCTION
12