manualshive.com logo in svg
background image

WARRANTY

Zetron warrants that all equipment manufactured by or sold under Zetron label is
free from defects in material and workmanship at the time of shipment. For your
convenience, Zetron may purchase and supply items manufactured by others.
This will be disclosed to you. In these cases other warranties may apply. Consult
with Zetron for specific details. Zetron’s warranty extends one year from date of
shipment and covers parts and labor. Buyer must provide written notice to Zetron
within the warranty period of any defect. If the defect is not the result of improper
use, service, maintenance or installation, and if the equipment has not been
otherwise damaged or modified after shipment, Zetron shall either replace or repair
the defective parts or replace the equipment or refund the purchase price at
Zetron’s option, after return of such equipment by buyer to Zetron. Shipment shall
be paid for by the buyer. No credit shall be allowed for work performed by the
buyer. Equipment found to be not defective shall be returned at buyer’s expense
and testing and handling expense shall be borne by the buyer. Out-of-warranty
repairs will be invoiced at the current Zetron hourly rate plus the cost of needed
components.

LIMITATION OF LIABILITY

Zetron makes no representation with respect to the contents of this document
and/or the contents, performance, and function of any accompanying software and
specifically disclaims any warranties, expressed or implied, as to merchantability,
fitness for purpose sold, description, or quality.

Further, Zetron reserves the right to revise this document or the accompanying
software and to make changes in it from time to time without obligation to notify
any person or organization of such revisions or changes.

This document and any accompanying software are provided “as is.” Zetron shall
not under any circumstances be responsible for any indirect, special, incidental, or
consequential damages or losses to the buyer or any third party arising out of or
connected with the buyer’s purchase and use of Zetron’s products or services.

Содержание CellPhone Detector Plus

Страница 1: ...allowed for work performed by the buyer Equipment found to be not defective shall be returned at buyer s expense and testing and handling expense shall be borne by the buyer Out of warranty repairs w...

Страница 2: ...ges into other areas This guide provides detailed information about the CellPhone Detector Plus For best operation please carefully read all the information in this guide prior to using or installing...

Страница 3: ...a small control room hospital room or meeting room place the CellPhone Detector Plus close to the sensitive equipment but away from outside windows Set the threshold to MEDIUM Sensitive Equipment If a...

Страница 4: ...pieces of equipment place an additional CellPhone Detector Plus in the hallway leading to the area Set the threshold to NEAR FEATURES CONTROLS The features and controls you need to be familiar with ar...

Страница 5: ...g functions VOICE I O UP The alarm is a series of beeps followed by a voice message This is useful when self enforcement is desired DOWN The alarm consists of beeps only Useful to alert facilities per...

Страница 6: ...signals See Auto Registration on page 9 for more details on the operation of this function DOWN The Auto Registration mode is not activated and short duration transmissions are ignored 4 SENSITIVITY A...

Страница 7: ...e volume setting During an alarm pressing this button puts the CellPhone Detector Plus into an audio alarm mute mode that lasts for 90 seconds Pressing this button while the CellPhone Detector Plus is...

Страница 8: ...is the front panel flashing light The Mute Mode lasts for about 90 seconds but can be canceled by simply pressing the TEST MUTE button OUTPUTS The CellPhone Detector Plus has two outputs audio and al...

Страница 9: ...lus checks to see if an RF signal is still present If no RF signal is present the alarm output returns to the high impedance state This allows the alarm output to be used as a trigger to count the num...

Страница 10: ...phone is ON For analog cellular phones these Auto Registration signals occur about every 30 minutes and last for only about 125 ms When a cellular phone is turned on it checks an internal counter to...

Страница 11: ...your application then it may also be desirable to turn off the Flashing LED on the front of the unit and use the remote Alarm Output For more information about placement see TYPICAL APPLICATIONS on p...

Страница 12: ...e VOICE I O DIP switch to the UP position to enable the voice alarm message or to the DOWN position for a beeps only alarm This is the left most switch on the DIP switch located above the ON OFF switc...

Страница 13: ...w Battery Conditions When the charge in the batteries is low the CellPhone Detector Plus will sound a low battery alert consisting of single brief beep or tone approximately every 6 minutes Once the l...

Страница 14: ...wall lift it up then away 3 Locate the four back cover screws and remove them 4 Remove the back cover and replace the four batteries according to the polarity diagram in the battery case 5 Re secure t...

Страница 15: ...ency Response 400 2000 MHz optimized for 810 1950 MHz Detection Distance 2 17 m minimum line of sight user adjustable 20 30 m typical Alarm Message Pre recorded at factory English is standard Other la...

Страница 16: ...icient power Replace the batteries or use an external DC power source The CellPhone Detector Plus is alarming to transmissions outside the intended coverage area The sensitivity is set too high Turn t...

Страница 17: ...gle beep about every 6 minutes Batteries are low and need replacement My cellular phone is on but the CellPhone Detector Plus is not alarming The CellPhone Detector Plus only alarms when a cellular ph...

Страница 18: ......

Отзывы: