Connecting to Consoles 

 

5.

 

Replace the cover and the three screws. 

Connecting to Consoles 

The following table provides connection information for Zetron and third party 
equipment. In most cases, one of the modular connectors on the supplied cable must be 
cut off to access the wire leads. Each switch closure has been paired to match the pair 
assignment of T568 as shown in Table 1

 

Warning!

The Zetron Desktop Keypad should not be hooked directly to 
loads that demand a true contact closure. For more detail, 

refer to the switch ratings in Specifications on page 7

Table 1 – Zetron Desktop Keypad cable connections 

Pin 

Wire Color T568A 

Wire Color T568B 

Signal 

1 White/Green  White/Orange 

Switch 

Common 

Green 

Orange 

Switch 2 Normally Open 

3 White/Orange  White/Green 

Switch 

Common 

Blue 

Blue 

Switch 1 Normally Open 

5 White/Blue  White/Blue 

Switch 

Common 

Orange 

Green 

Switch 3 Normally Open 

7 White/Brown  White/Brown 

Switch 

Common 

Brown 

Brown 

Switch 4 Normally Open 

 

 

 

9

 

Содержание 025-9636A

Страница 1: ...Zetron Desktop Keypad 025 9636A...

Страница 2: ...andling expense shall be borne by buyer Out of warranty repairs will be invoiced at the then current Zetron hourly rate plus the cost of needed components THE FOREGOING WARRANTY AND THE THIRD PARTY MA...

Страница 3: ...ordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the u...

Страница 4: ...ld produce a short circuit that could cause fire electrical shock or equipment damage Remove rings watches and other metallic objects from your body before opening equipment These could be electrical...

Страница 5: ...Contents Contents Overview 6 Specifications 7 Installation 8 Attaching a Cable 8 Connecting to Consoles 9 5...

Страница 6: ...n Desktop Keypad P N 950 1105 is a robust 4 button keypad designed for high quality ruggedness and the ability to connect directly to digital inputs in Zetron and third party equipment Figure 1 Zetron...

Страница 7: ...50 million cycles at 5V Switch voltage rating 2 to 12 V DC Switch current rating 10 uA to 10 mA Environmental Operating temperature 0 to 60 degrees C Storage temperature 10 to 70 degrees C Humidity 95...

Страница 8: ...standard Ethernet patch cable T568A B 1 Attaching or replacing a cable to the Zetron Desktop Keypad Remove the three screws as shown in the following figure 2 3 4 Remove the cover Connect the cable t...

Страница 9: ...The Zetron Desktop Keypad should not be hooked directly to loads that demand a true contact closure For more detail refer to the switch ratings in Specifications on page 7 Table 1 Zetron Desktop Keyp...

Страница 10: ...plication requires each switch to be isolated then these circuit board traces can be cut To do so you ll need to remove the circuit board from the metal housing as these traces are located on the top...