1. Checking the air conditioning system.
1
- Economic friendly refrigerant : R134a 0.7~0.85 kg.
The presence of air and water in the system could jeopardize its efficiency.
- The air is uselessly compressed by the compressor and no cooling effect is produced.
- The moisture has a tendency rise to obstructions which prevent the cooling efficiency.
2
- Check belt tension ; when finger pressure is applied to the mid-point between both pulleys.
3
- Condenser fins must always be duly clean using water or an air set.
2. Checking the air conditioning system charge
(1) Check the refrigerant charge.
A. Run the engine at 1500 rpm.
B. Set the air conditioning system in the coldest for 5 minutes.
C. Check sight glass for clear sight or cloudy.
Caution:
If the air conditioning system is operated without being charged, The lubrication in
the compressor can cause damage.
3. Diagnosing malfunctions
(1) Tracing faults
SYMPTOM
CONDITION
CAUSE
REMEDY
1.Compressor
Abnormal sound
Inlet sound
Outlet sound
Insufficient Lub.
Replenish
Belt tension release
Adjust
Release the bracket
Tighten the bolts
Clutch fail
Check
Abnormal revolution
Inlet cause
Damaged parts
Check, replace
Slip the clutch
Check, replace
Not Lub.
Replenish
Outlet cause
Belt tension released
Adjust
Refrigerant or oil
leakage
Refrigerant or oil
leakage
Sealing washer
damaged
replace
Head bolt released
Tighten the bolts
D-ring damaged
Replace
Excessivepressure
Low, High
pressure
Insufficient refrigerator
Adjust
Compressor
Replace
CABIN
110
Содержание UTILIX HT 45
Страница 1: ...OPERATOR S MANUAL UTILIX HT 1 2018 45 Tractor is Zetor Since 1946 55...
Страница 3: ...2...
Страница 9: ...8...
Страница 11: ...10...
Страница 33: ...32...
Страница 39: ...38...
Страница 69: ...68...
Страница 101: ...100...
Страница 113: ...112...
Страница 123: ...122...
Страница 131: ...130...
Страница 133: ...132...
Страница 136: ...135...
Страница 138: ...Made in EU www zetor com zetor zetor com...