(2) How to check the air conditioning system with the needle of high low gauge
To connect with manifold pressure gauge can find the cause of air conditioning system.
Because manifold pressure gauge is various sensibly (Ambient Temp. is based on 30~35 °C)
Caution: Operating E/G RPM 1500~2000 is must, and so to that you can check the correct cause and air
conditioning. (In case below the figure of indicated pressure gauge has some clearance, confirm with
approximate indicated needle data.)
Gauge pressure conversion
lb/in
2
=PSI
1 kg/cm
2
=14,223 lb/in
2
(Ex) 200 PSI=14 kgf/cm
2
SYMPTOM
CONDITION
CAUSE
REMEDY
2. Motor
Weak from
pressure or Don't
work
Motor is normal
Air inlet clogged
Remove
Evaporator freezing
Controlling minimum
pressure
Ventilator switch
damage
Replace the switch
Compressor
Replace
Motor is abnormal
Motor failure
Replace
Wire cut
Replace
Air leakage
Duct leakage
Check, tighten
Unable to control
the fan
Motor
Air volume control switch
failure
Check, tighten
Motor is abnormal
Motor failure
Replace