Bleeding the fuel system
Dry air cleaner maintenance instructions
Before bleeding place a suitable container under
the engine to collect dripping fuel from the filter and
injection pump.
F_02_93a
1. Prime the fuel system with several strokes of the
manual control of the priming pump (1).
2. Release the screw (2) of the fitting of the fuel inlet to the
filter and let the foam escape.
3. Retighten the screw and repeat the procedure until after
releasing of the screw clear fuel starts to continuously flow
from the filter.
E707
4. Bleed the injection pump in the same way.
5. Do the bleeding with the screw (3) positioned on the
pump body.
E708
Do air filter maintenance accordingly:
1. heave the front bonnet
2. release the clamps of air filter lid (marked with arrows)
3. remove air filter lid (1)
G712