Description of minor errors of the EHR-B electro-hydraulic system
F_02_174
Flashing combination of
the diagnostic LED (7).
Error location
Possible cause of the error
Long
pause
No.
of
flashes
Short
pause
No.
of
flashes
3x
1x
Right dynamometric pin
(A)
Faulty dynamometric pin
3x
2x
Left dynamometric pin (A) Faulty contact or interrupted conductor of the
dynamometric pin
Short-circuit of the dynamometric pin
conductor
Possible overloading of the dynamometric
pin
3x
4x
Lowering speed control
(3)
Faulty potentiometer of the control (3)
Faulty contact or interrupted conductor of the
control
3x
6x
Control setting switch (6) Faulty potentiometer of the switch (6)
Faulty contact or interrupted conductor of the
switch
ELECTRO-HYDRAULIC SYSTEM
146
Содержание FORTERRA HSX Series
Страница 1: ...FORTERRA HSX 120 130 Tractor is Zetor Since 1946 140 120 130 140 OPERATOR S MANUAL 2 2018...
Страница 3: ...2...
Страница 51: ...NOTES 50...
Страница 75: ...NOTES 74...
Страница 115: ...NOTES 114...
Страница 139: ...NOTES 138...
Страница 153: ...NOTES 152...
Страница 168: ...167...
Страница 169: ...Fuse panel B FHSX18N001 ELECTRIC INSTALLATION 168...
Страница 220: ...219...
Страница 222: ...www zetor com zetor zetor com Made in EU...