background image

5/12 

 

Kv values for various settings for the valve Fig. 221 version H (brass): 
 
 
 
 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
10.  Causes of operating malfunctions and their elimination 
 

When searching for the malfunctioning of the valve safety rules must be observed 

 

 

Malfunction 

Possible cause 

Solution 

No flow 

Valve closed 

Open the valve 

Low flow 

Valve not sufficiently open 

Open the valve 

Contaminated filter 

Clean or replace the strainer 

Clogged pipeline system 

Check the pipe line 

Difficult valve control 

Dry stem 

Oil the stem 

Leakage on the stem 

Damaged o-rings 

Replace the o-rings 

 

Leakage on the seat 

Improper closing 

Tighten  the  hand  wheel  without  using 
auxiliary tools 

Damaged seat or disc 

Replace  the  valve.  Contact  the  supplier  or 
manufacturer 

Too high pressure difference 

Check  that  the  valve  is  installed  in 
accordance  with  the  flow  direction 
marked on the valve. 

Medium contaminated with solid objects 

Clean the valve. Install a strainer upstream. 

 
 
11. Decommissioning 
 

 

After  decommissioning  and  dismantling  the  valves  must  not  be  disposed  of  with  household  waste.  Valves  are  made  of  recyclable 
materials.  Deliver them to a recycling centre. 

 
 

DN 

15 

20 

25 

32 

40 

50 

Type  

60 

Body material 

Wheel position 

Valve flow Kv coefficient  [m

3

/h]

 

0,5 

1,00 

2,71 

2,48 

4,52 

5,13 

7,07 

1,0 

1,27 

3,55 

3,35 

6,50 

7,76 

9,67 

1,5 

1,43 

3,88 

3,91 

7,72 

9,32 

11,37 

2,0 

1,60 

4,12 

4,35 

8,58 

10,62 

12,98 

2,5 

1,76 

4,33 

4,80 

9,44 

12,01 

14,57 

3,0 

2,00 

4,53 

5,40 

10,31 

13,74 

16,29 

3,5 

2,22 

4,75 

6,17 

11,09 

15,18 

18,26 

4,0 

2,34 

4,94 

6,80 

12,32 

16,53 

20,34 

K

sig

 

2,28 

7,79 

11,91 

21 

33,66 

49,81 

Отзывы: