PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII)
#Doc No. GLT-215-7-2
PAGE 1
Issue: 1.08 Author: TE/NJ Date: 26/05/2017
TABLE OF CONTENTS
WHAT TO DO IF THE FIRE ALARM PANEL SHOWS A FAULT (YELLOW LED) ............................................................................................... 2
1. FIRE ALARM CONTROL PANEL SAFETY ISSUES ..................................................................................................................................... 3
2. THE PURPOSE OF A FIRE ALARM SYSTEM ............................................................................................................................................ 3
3. USER RESPONSIBILITIES & MAINTAINENCE OF THE FIRE ALARM SYSTEM, INCLUDING THE FACP & ITS INTEGRAL PSE ...................... 4
DAILY INSPECTION ....................................................................................................................................................................... 4
WEEKLY TEST (YOU MAY WISH TO TEMPORARILY DISCONNECT THE AUX RELAY DURING THE FOLLOWING TESTS) ................... 4
QUARTERLY TEST (TO BE CARRIED OUT BY AUTHORISED SERVICE PERSONNEL ONLY) ............................................................... 4
ANNUAL TEST (TO BE CARRIED OUT BY AUTHORISED SERVICE PERSONNEL ONLY) .................................................................... 5
EVERY FIVE YEARS (TO BE CARRIED OUT BY AUTHORISED SERVICE PERSONNEL ONLY).............................................................. 5
4. PANEL INDICATIONS & CONTROLS ....................................................................................................................................................... 7
4.1 PANEL INDICATIONS .............................................................................................................................................................. 6
4.2 PANEL CONTROLS .................................................................................................................................................................. 6
4.3 IN THE EVENT OF AN ALARM ................................................................................................................................................ 6
4.4 ACCESS LEVELS ...................................................................................................................................................................... 6
5. THE FIRE CONDITION ........................................................................................................................................................................... 8
5.1 HOW THE QUATRO INDICATES AN ALARM ............................................................................................................................ 8
5.2 HOW TO TURN OFF THE ALARM SOUNDERS ......................................................................................................................... 8
5.3 A SECOND ALARM SIGNAL FROM A NEW DETECTION ZONE ................................................................................................. 8
5.4 TURNING ON THE ALARM SOUNDERS FROM THE FACP (TO EVACUATE THE BUILDING) ....................................................... 9
5.5 RESETTING THE PANEL........................................................................................................................................................... 9
6. THE FAULT CONDITION ...................................................................................................................................................................... 10
6.1 FAULT INDICATIONS ............................................................................................................................................................. 10
6.2 WHAT TO DO IF A FAULT CONDITION OCCURS .................................................................................................................... 11
7. DISABLEMENTS .................................................................................................................................................................................. 12
7.1 REASONS FOR DISABLING CERTAIN PARTS OF A FIRE ALARM SYSTEM ................................................................................ 12
7.2 TO DISABLE A ZONE ............................................................................................................................................................. 12
7.3 TO DISABLE A POINT ............................................................................................................................................................ 12
7.4 TO DISABLE A SOUNDER ...................................................................................................................................................... 12
7.5 TO DISABLE A RELAY ............................................................................................................................................................ 12
8. SYSTEM DESCRIPTION ........................................................................................................................................................................ 13
FIRE ALARM SYSTEM SUMMARY ............................................................................................................................................... 13
DETAILED LOOP CONTENTS: LOOP 1 .......................................................................................................................................... 20
DETAILED LOOP CONTENTS: LOOP 2 .......................................................................................................................................... 21
DETAILED LOOP CONTENTS: LOOP 3 .......................................................................................................................................... 24
DETAILED LOOP CONTENTS: LOOP 4 .......................................................................................................................................... 25
9. FIRE ALARM LOG BOOK ..................................................................................................................................................................... 27
MAINTENANCE WORK ............................................................................................................................................................... 29
MAINTENANCE WORK (CONTINUED) ........................................................................................................................................ 30
UNWANTED (FALSE) ALARMS (CONTINUED) ............................................................................................................................. 32
ALL EVENTS OTHER THAN MAINTENANCE WORK OR FALSE ALARMS ....................................................................................... 33
ALL EVENTS OTHER THAN MAINTENANCE WORK OR FALSE ALARMS (CONTINUED) ................................................................ 34
10. COMMISSIONING THE SYSTEM, INCLUDING POWER SUPPLY EQUIPMENT P.S.E. ............................................................................ 35
10.1 DESIGN, INSTALLATION & COMMISSIONING CERTIFICATES .............................................................................................. 35