ZES EVC05 Series Скачать руководство пользователя страница 3

English - 2

© 2021 ZES - All rights reserved

IB v3.0.0 2021

SAFETY INFORMATION

CAUTION

RISK OF ELECTRIC SHOCK:

CAUTION:

 

VESTEL ELECTRIC VEHICLE CHARGER DEVICE SHALL BE MOUNTED BY A LICENSED OR 

AN EXPERIENCED ELECTRICIAN AS PER ANY REGIONAL OR NATIONAL ELECTRIC REGULATIONS AND 

STANDARDS IN EFFECT.

 

CAUTION

AC grid connection and load planning of the electric vehicle charging device 

shall be reviewed and approved by authorities as specified by the regional 

or national electric regulations and standards in effect. For multiple electric 

vehicle charger installations the load plan shall be established accordingly. The manufacturer shall 

not be held liable directly or indirectly for any reason whatsoever in the event 

of damages and risks that are borne of errors due to AC grid supply connection or load planning.

IMPORTANT - Please read these instructions fully before installing or operating

SAFETY WARNINGS

• 

Keep this manual in a safe place. These safety and operating instructions must be kept in a 

safe place for future reference.

• 

Check that the voltage marked on the rating label and do not use charging station without 

appropriate mains voltage.

• 

Do not continue to operate the unit if you are in any doubt about it working normally, or if it 

is damaged in any way - switch off the mains supply circuit breakers (MCCB and RCCB) in 

upstream distribution panel. Consult your local dealer.

• 

The ambient temperature range during charging should be between –25 °C and +50 °C (without 

direct sunlight) and at a relative humidity of between 5 % and 95 %. Use the charging station 

only within these specified operating parameters.

• 

The device location should be selected to avoid excessive heating of the charging station. High 

operating temperature caused by direct sunlight or heating sources, may cause reduction of 

charging current or temporary interruption of charging process.

• 

The charging station is intended for outdoor and indoor use. It can also be used in public places.

• 

To reduce the risk of fire, electric shock or product damage, do not expose this unit to severe 

rain, snow, electrical storm or other severe weathers. Moreover, the charging station shall 

not be exposed to spilled or splashed liquids.

• 

Do not touch end terminals, electric vehicle connector and other hazardous live parts of the 

charging station with sharp metallic objects.

• 

Avoid exposure to heat sources and place the unit away from flammable, explosive, harsh, or 

combustible materials, chemicals, or vapors.

• 

Risk of Explosion. This equipment has internal arcing or sparking parts which should not be 

exposed to flammable vapors. It should not be located in a recessed area or below floor level.

• 

This device is intended only for charging vehicles not requiring ventilation during charging.

• 

To prevent risk of explosion and electric shock, ensure that the specified Circuit Breaker and 

RCD are connected to building grid.

Содержание EVC05 Series

Страница 1: ...User Manual ELECTRIC VEHICLE CHARGER EVC05 Series...

Страница 2: ...OMPONENTS 8 2 PLUG CHARGING CABLE to EACH SOCKET 9 2 1 AC22KWSOCKETOUTLET 9 2 2 SCHUKO SOCKET OUTLET Optional 10 3 CHARGING SCENARIOS 11 3 1 AC 22 kW SOCKET OUTLET 12 3 1 1 VEHICLE CONNECTION CHARGING...

Страница 3: ...tream distribution panel Consult your local dealer The ambient temperature range during charging should be between 25 C and 50 C without direct sunlight and at a relative humidity of between 5 and 95...

Страница 4: ...e there is no risk of explosion Charging station should be installed in areas where there is no risk of falling objects around which may damage the station The installation surface of the station shou...

Страница 5: ...arge cable is well positioned thus it will not be stepped on tripped over or subjected to damage or stress Do not forcefully pull the charge cable or damage it with sharp objects Never touch the power...

Страница 6: ...ries Name Coding EVC05 AC EVC05 Electric Vehicle AC Charger Mechanical Cabinet 05 1st Asterisk can include Outlet Quantity and Rated Power 44 22kW with dual outlet 3Phase Supply Equipment 22 11kW with...

Страница 7: ...Control WebConfig UI Built in DC residual current sensor DC 6 mA Display Color 10 4 TFT LCD with resistive touchscreen user interface Built in MID meter Class B MID meter Eichrecht conformity optiona...

Страница 8: ...NICAL SPECIFICATIONS Material Metal Panel Protection Degree Ingress Protection Impact Protection IP54 IK10 In screen and sockets IK08 Dimensions 1530 0 mm Height x 575 0 mm Width x 205 0 mm Depth Dime...

Страница 9: ...IB v3 0 0 2021 GENERAL INFORMATION 1 INTRODUCTION OF THE PRODUCT COMPONENTS 4 6 7 8 5 1 3 2 1 Display 2 ALS Sensor 3 RFID Card Reader 4 Notification LED 5 Door Lock Mechanism 6 AC Type 2 Socket Outle...

Страница 10: ...from AC type2 outlets 2 EVs to charge from schuko outlets Explanation to plug unplug the charging socket to from the outlet 2 1 AC 22 KW SOCKET OUTLET Open the front cover of the available socket outl...

Страница 11: ...ard Sequentially please follow the steps as below Select the requested schuko outlet from the touchscreen Tap your authorised RFID Card to the RFID reader under the touchscreen The lock mechanism insi...

Страница 12: ...1 you may first select the socket you want to use from the touchscreen of the charging station and tap your authorised RFID card to the reader and then plug your charging cable to that selected socke...

Страница 13: ...eserved IB v3 0 0 2021 3 1 AC 22 kW SOCKET OUTLET 3 1 1 VEHICLE CONNECTION CHARGING 1 Connect charging cable to the available socket and select that socket from the touchscre en 2 Tap your RFID card o...

Страница 14: ...13 IB v3 0 0 2021 2021 ZES All rights reserved 3 It may take a few seconds for charging session to start Charging state can be seen in charging page While charging charging state can be seen in the ma...

Страница 15: ...English 14 2021 ZES All rights reserved IB v3 0 0 2021 3 1 2 STOP CHARGING 1 Click Stop Charging to end the charging session 2 Tap your RFID card or scan QR Code to stop charging...

Страница 16: ...English 15 IB v3 0 0 2021 2021 ZES All rights reserved 3 Disconnect the charging cable After disconnection you will automatically move to the main screen...

Страница 17: ...ved IB v3 0 0 2021 3 2 SCHUKO SOCKET OUTLET Optional 3 2 1 VEHICLE CONNECTION CHARGING 1 Connect charging cable to the available socket and select that socket from the touchscre en 2 Tap your RFID car...

Страница 18: ...de up the schuko cover and connect the schuko charging cable Make sure that schuko cover is closed properly after the connection to be able to start charging 3 It may take a few seconds for charging s...

Страница 19: ...English 18 2021 ZES All rights reserved IB v3 0 0 2021 While charging charging state can be seen in the main menu 3 1 2 STOP CHARGING 1 Click Stop Charging to end the charging session...

Страница 20: ...ed after tapping the RFID card and you will be able to slide up the schuko cover to be able to reach and disconnect the charging cable 3 Disconnect the charging cable After disconnection you will auto...

Страница 21: ...Finished Constant Red Fault 4 sec Ventilation Required Blinks Red 2 4 seconds OFF 1 2 seconds ON Park Automation System disabled charging Constant Purple Charging paused due to power optimizer low cu...

Страница 22: ...ontact with open wire As a result the current returning through then neutral wire is reduced The difference in current between the live and neutral wire is called residual current RCCB is designed suc...

Страница 23: ...or error condition If the status information LED is constant red turn off the charging station and turn on again If the status information LED is constant red turn off the charging station and turn o...

Страница 24: ...sure unit ensure that there is no failure on your vehicle or on the charging plug that may cause a residual current before resetting the tripped residual current device After ensuring that there is no...

Страница 25: ...Manufacturer Name Vestel Electronics Address Vestel Elektronik Sanayi ve Ticaret A S Organize Sanayi B lgesi 45030 Manisa Turkey...

Отзывы: