background image

LED Display 

1. Temperature 

Range of display : -9℃ ~ 85℃  

Below -9℃ will display as negative (-). 

2. Humidity 

Range of display : 0 ~ 99%RH 

5. LAMP Replacement Notification (Red color) 

Lights up : Replace the LAMP (LAMP lifespan : 10,000 hours) 

Blinks : Contact service center when the same notification is 

displayed after replacing the lamp due to circuit break or lamp 

power problem. 

* How to reset the notification 

1. Cumulative usage time has to be reset when replacing the 

LAMP. 

2. Turn on the power switch while pressing the fan speed 

control dial. 

3. LAMP notification will blink and reset the cumulative usage 

time when pressing the fan speed control dial for 3 seconds. 

4. Release fan speed control dial. 

6. FAN Replacement Notification (Red color) 

Lights up : Contact service center due to FAN error. 

3. Fine dust 

Displays PM2.5 and PM10 fine dust concentration 

consecutively. 

Effective measurement range : 0 ~ 500ug/m

4. Fan speed 

5 levels are shown as bars. 

Содержание SV-1010

Страница 1: ...zerona Space Sterilizer User Manual SV 1010 STR SOLUTION...

Страница 2: ...Table of Contents Parts 3 Product Overview 4 Operation Stand Assembly 5 Operation Product Operation 6 LED Display 7 Filter Replacement 8 Specification 9 Safety Precaution 10 Warranty 11...

Страница 3: ...Parts Body DC Adapter User Manual Warranty Stand 2ea Remote Control...

Страница 4: ...lter Guide Air Vent Body front view LED Display Fan Speed Control Dial Stand Fan Speed Fine Dust Humidity Temperature LAMP Replacement Notification FAN Replacement Notification IR Receiver LED Display...

Страница 5: ...Operation Stand Assembly 2 Use screws to assemble each stand at each hole Flip the body back to original direction when the screws are assembled well 1 Flip the body upside down...

Страница 6: ...M2 5 Button Displays PM2 5 fine dust concentration PM10 Button Displays PM10 fine dust concentration Fan speed MAX MIN Button Adjust the fan speed to MAX MIN at once 1 Turning on the product 1 1 Conne...

Страница 7: ...o reset the notification 1 Cumulative usage time has to be reset when replacing the LAMP 2 Turn on the power switch while pressing the fan speed control dial 3 LAMP notification will blink and reset t...

Страница 8: ...the Front Cover 2 Pull the Filter Guide forward to lift the Filter 3 Pull the Filter Assemble the new filter in the following order filter filter guide front cover Notice Recommended lifespan of a fi...

Страница 9: ...0 Hz 1 5A Rated Output DC12V 3 5A Power Consumption 12W Certification Adapter certifications used Dimension W500 x D140 x H405 mm Weight 9 8kg Applicable Area 109m2 Country of Origin Republic of Korea...

Страница 10: ...ce Do not install the product near heat generating equipment It causes deformation discoloration or fire Do not install the product in a damp area and keep away from splashing rain or water It has a r...

Страница 11: ...Warranty Model No SV 1010 Warranty period 1 year from purchase date Serial No At the back of the product Purchase date 20 Name Phone No Address Note...

Отзывы: