Anytime Anywhere, The Fresh Air for Me
ZERONA
USER MANUAL
ㅣ
07
• The sterilization lamp and filter replacement cycle in the sterilizer is one year.
(When replacing the sterilization lamp, replace the filter as well.)
(If you use it for a short time during the day, you can use it for a longer period.)
• For the sterilization lamp and filter in the sterilization device, be sure to use
the genuine filter provided by MADEKR Co., Ltd.
• The replacement cycle of the sterilization lamp in the sterilizer may vary depending
on the environment of use.
• There may be a new filter smell at first, but it will disappear naturally after using
the product for more than a day.
• Avoid using perfumes, air fresheners or sprays around the product. The filter life will be shortened.
Power button starts or stops the air sterilizer (purification) operation.
Starts or stops mood, feeding, etc.
• One-touch smart dimming function allows you to adjust the brightness
from level 1 to level 3
The wind speed can be adjusted from stage 1 to stage 3.
• Filter management is important for purification function. If you clean the
filter with a vacuum cleaner or soft brush once every two weeks, it can
be used for a longer period.
*
This filter cannot be washed with water. Never wash the filter,
as it may seriously damage the filter performance.
• Cleaning the exterior of the space sterilizer is also easy for filter
management. Use a vacuum cleaner to remove dust from the air inlet
and air outlet.
Precautions
for replacing
sterilization
lamps
Operation
panel
TiP
• Sterilization lamps and filters must be genuine products provided
by MADEKR Co., Ltd., and the use of counterfeit products may cause
performance degradation.
Purchase Inquiry
070.4116.8776
ㅣ
www.madekr.co.kr
How to buy a filter
1. After connecting the power plug to the outlet, press the power button
for about 1 second to start the air sterilizer.
2. You can adjust the sterilization intensity by pressing the wind speed button.
Stage 1
(sleep mode)
ㅣ
Stage 2
(weak wind)
ㅣ
Stage 3
(strong wind)
Air
sterilization
(purifica-
tion)
function
Level 1 (sleep mode)
Use during normal or sleep
Level 2 (weak wind mode)
Large area or crowded space
Level 3 (Strong wind mode)
When you want to volatilize sterilizing
substances in the space
Notes when
selecting
wind speed
7. Loosen the 4 screws connected
to the sterilization lamp.
9. Remove the lamp in the separated
sterilizer and replace it with
a new accessory.
8. Remove the bracket by pushing it
down as indicated by the arrow.
Tips to
make your filter
last longer