background image

zero

HOME AUTOMATION

Z01 - SLIDING GATE

PG7

MANUAL RELEASE

To open manually the gate in case of electric power failure or in case of damage, follow the 

below steps:

01. Open the protection cover to acess the key 

hole for the release. Insert the key and turn 

it 90°.

02.  Pull the lever towards the outside, and 

you can now open/close the gate manually.

NOTE

 : So that the automation will operate 

normally, close the unlock and turn the key to 

the original position. 

Check that the distance between rack and motor remains unchanged and this engages the teeth 

of the pinion of the engine correctly (over time can happen some distortion).

Lubricate all systems/axis of movement of the gate. Lightly lubricate with spray the rack and 

pinion.

Periodically check the amount of oil within the operator. For medium-low frequency of use, an 

annual check is enough, for more intensive use it is recommended every 6 months. To make 

filling, unscrew the cap and load until the level.

04. MAINTENANCE

Check all screws of the automation such as the fixing plate to the ground, the plates 

of the limit switches, motor and the gear rack.

ADJUSTING THE TORQUE TRANSMISSION

To adjust the torque transmission, act on the 

screw placed on the engine:

- Rotate the screw clockwise to Increase the 

torque transmission.

- Rotate the screw anticlockwise to decrease 

the torque transmission.

CAUTION: 

THE  MOTOR  IS  PROVIDED  WITH 

THE CLUTCH REGULATED AT MAX. SHOULD BE 

ROTATE  ANTICLOCKWISE  THE  SCREW,  UP  TO 

ACHIEVE THE OPTIMAL ADJUSTMENT.

Содержание Z01.03

Страница 1: ...zero HOME AUTOMATION Z01 SLIDING GATE PG1 USER MANUAL AND CONFIGURATION Z01 REV01 2018 IT EN FR zero HOME AUTOMATION Z01 03 SLIDING GATE MOTOR SUPPLY 230V...

Страница 2: ...zero HOME AUTOMATION Z01 SLIDING GATE PG2 zero HOME AUTOMATION...

Страница 3: ...f danger ZERO SRLS is not responsible for the improper use of the product or other use than that for which it was designed ZERO SRLS is not responsible if safety standards were not taken into account...

Страница 4: ...wer Supply 230Vac 50 60Hz Operating temperatures 25 C to 65 C Power 650W Thermal protection 130 C Current 2 4 A Protection class IP44 RPM 1400 Working frequence intensive Capacitor 25 F Opening time 1...

Страница 5: ...e at an angle of 90 and mark the place to make the holes for the bushings Must make the mark at the center of the oval holes 02 Drill four holes with 18mm on foun dation Place M10 steel anchors on the...

Страница 6: ...types of lubricant between rack and pinion FL ASH LAM P ANTENNA CONTROL BOARD MOTOR PH OTOCELL PH OTOCELL KE Y SEL ECTOR TIPICAL INSTALLATION It is important to use mechanical stoppers in the opening...

Страница 7: ...tems axis of movement of the gate Lightly lubricate with spray the rack and pinion Periodically check the amount of oil within the operator For medium low frequency of use an annual check is enough fo...

Страница 8: ...n t close Unlock motor and move the gate by hand to closed position Lock motor again and turn off power supply for 5 se conds Reconnect it and send start signal using transmitter Gate opened but didn...

Страница 9: ...here is some security systems malfunction photocells safety edges etc 1 Close with a shunt all safety systems on the control board check manual of the control board in question If the automated system...

Страница 10: ..._____________________________________________________ _____________________________________________________________________ _____________________________________________________________________ ______...

Страница 11: ...zero HOME AUTOMATION Z01 SLIDING GATE PG11 zero HOME AUTOMATION...

Страница 12: ...zero HOME AUTOMATION Z01 SLIDING GATE PG12 zero HOME AUTOMATION ZERO SRLS Via ROMA 25 A ALTAVILLA VIC ITALIA info miozero it www miozero it...

Отзывы: