3
May 21, 2019
Author: Rudi
Version: 1
Keep a first AID kit available for burns. Learn how to proceed to perform emergency care in case of
injury.
Avoid accumulating liquid or grease on the table, oven or other parts of the stove.
Leakage
For better safety, when the stove is not in use, close the gas cylinder.
In case of existing leakages or realizing gas odor inside the house, take the following steps:
1. Close the gas cylinder on the installation which supplies the stove;
2. Do not light any flames or operate tools that generate sparks;
3. Do not operate electric switches;
4. Open windows and doors, improving room ventilation.
Contact Technical Support if the leak is in the stove and, specialized companies or gas distributors if
the leak is in the supply network or cylinder.
3- INSTALLATION AND POSITION OF THE STOVE
When installing the stove, place it at a clear distance of 20 cm on the sides and back, on a flat and
level surface.
Avoid installing the stove in wet and windy places. Install the stove in a safety distance from
flammable and non heat resistant materials.
When installing the stove on a flat surface, make sure that it cannot move or slide as it may cause
accidents.
Check if there is gas leaks on the distribution line or at the cylinder using foam soap, never use sparks
or flames, as it may result in a fire.
4 – GAS INSTALLATION
Only use a gas regulator and quality hoses according to your countries technical standards.
Use clamps to fix the gas hose on the stove and on the gas network or cylinder.
The entry point of the gas (installation, central gas, and cylinder) should be located on the same side
of the gas entry on the stove, in the event of it being fitted with a single-sided output. The gas hose
should not pass through the back of the stove, but if it is not possible, it is necessary to use flexible
metal hose (please check your countries technical standards about the entry point of gas).
To minimize risk of accidents, the gas cylinder must be installed on the outside of the residence.
1. Gas cylinder;
2. Gas pressure regulator, must be installed according to your countries technical standards.
3. Hose clamp;
4. PVC plastic hose – please check your country technical standards.