7.10 

Removing or Replacing Reclaimer Inlet  
Baffle – Figure 30 

 

 

600 and 900 cfm reclaimers only with bolt-on tops. 

 

When  using  lightweight  media  such  as  agricultural 
media  or  very  fine  media  (180  and  finer),  as  noted  in 
Paragraph 1.9.6, good media may be carried over to the 
dust  collector.  To  prevent  lightweight-media  carryover, 
the  reclaimer  inlet  baffle  can  be  removed.  Review  the 
following  process  before  beginning  to  make  sure  all 
parts are available:  

 

Installation Notes: 

 

Make  sure  enough  13089  -  2"  adhesive-backed  gasket 
is available to replace compressed or damaged gaskets 
on the reclaimer upper flange (and lower hopper flange if 
the hopper is removed from the reclaimer). 

  300 cfm none required. Baffle is not removable. 

  600 cfm requires 6 ft for each flange. 

  900 cfm requires 7 ft for each flange 

 

Depending on conditions such as height and accessibility, 
it may be easier to replace the baffle if the reclaimer is 
removed  from  the  cabinet  (hopper/stand  on  900 
reclaimers). 
 

7.10.1 

Remove the flex hose from the reclaimer top. 

 
 

 
 
 

 

 

 

Figure 30 

 
 

7.10.2

  Remove  the  fasteners  securing  the  reclaimer 

top and remove the top. 
 

7.10.3

  Remove  the  two  bolts  (three  on  900  reclaimer) 

that  secure  the  baffle  to  the  side  of  the  reclaimer  inlet 
and remove the baffle through the top. 
 

7.10.4

  Remove all caulking residue.  

 

7.10.5

  If removing (not replacing) the baffle, remove the 

strip  gasket  from  the  inner  tube  and  install  the  baffle 
bolts  and  reclaimer  top.  If  replacing  the  baffle,  skip  to 
Paragraph 7.10.6.  
 

7.10.6

  When  replacing  the  baffle,  make  sure  the  strip 

gasket on the inner tube is in good condition and install 
the  new  baffle  in  reverse  order.  Apply  silicone  caulk  to 
the seam (opposite side of the mounting bolts) between 
the baffle and reclaimer body. Wipe the caulk smooth. 
 

7.10.7

  Inspect  the  strip  gasket  on  the  reclaimer  upper 

flange; replace it if damaged or compressed. 
 

7.10.8

  Install  the  reclaimer  top  and  allow  the  caulking 

to cure before putting the reclaimer into service. 

 
 
7.11 

Reverse-Pulse Dust Collector 

Refer  to  the  applicable  dust  collector  manual,  as  noted 
in Paragraph 1.1.1, for dust collector maintenance. 
 

 

Reclaimer Top and Inner 
Tube. Style may vary 
depending on reclaimer size.

2” Strip Gasket 

2” Strip Gasket 

Baffle 

U-Channel 

Baffle Nuts and Lock Washers 

Baffle Bolts and 
Flat Washers 

Reclaimer Body 

Содержание BNP 65

Страница 1: ...sible that the products described in this material may be combined with other products by the user for purposes determined solely by the user No representations are intended or made as to the suitabil...

Страница 2: ...ol It is used to alert you to potential physical injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death NOTICE Notice indicates information that is considere...

Страница 3: ...released 8 12 Media buildup in cabinet hopper 8 13 Static shocks 8 14 Dust leaking from cabinet 8 15 Dust leaking from dust collector 8 16 ACCESSORIES AND REPLACEMENT PARTS 9 0 Optional Accessories 9...

Страница 4: ...creened for oversize particles and returned to the reclaimer hopper for reuse Dust and fines entering the dust collector are removed from the air stream as they pass through the filters discharging cl...

Страница 5: ...and operate the same as the RPC 2 as shown in Figure 3 but instead of a dust drawer the collector sits atop a hopper which provides additional dust storage and empties into a 30 gallon drum Refer to...

Страница 6: ...brasive blasting because of the respiratory hazards associated with media containing free silica Slags are not recommended because they rapidly break down and are not recyclable 1 9 4 Silicon carbide...

Страница 7: ...al Compressed Air Consumption in CFM BNP Gun Jet Orifice Nozzle Orifice CFM PSI No 4 1 8 5 16 21 80 No 5 5 32 5 16 32 80 No 6 3 16 3 8 47 80 No 7 7 32 7 16 62 80 No 8 1 4 1 2 86 80 Using this combinat...

Страница 8: ...t collector pulse Refer to the dust collector owner s manual The line may be connected to the auxiliary air port on the cabinet plumbing as shown in Figure 6 WARNING Failure to observe the following b...

Страница 9: ...Shorting electrical components can result in serious injury or death from electrical shock or equipment damage Electrical power must be locked out and tagged out before performing any electrical work...

Страница 10: ...Media Hose to Metering Valve 900 cfm freestanding reclaimer only Hoses are already attached to 300 and 600 cfm reclaimers Figure 9 2 6 1 Refer to Figure 9 and attach the clear media hose from under t...

Страница 11: ...ch grommet 3 2 4 Ergo side extensions Position the curtain on the wall to be protected Use the curtain as a template and mark the top mounting point through the grommet Remove the curtain and drill a...

Страница 12: ...o make sure they function correctly When certain the table and tracks are aligned and level and that the workcar moves smoothly on all tracks tighten the leveling pad lock nuts and anchor the support...

Страница 13: ...unsupported parts may cause them to shift or topple and cause severe injury This is especially important with the use of turntables 4 3 1 Load and unload parts through either door 4 3 2 Parts must be...

Страница 14: ...ffects size of blast pattern Under normal conditions hold the nozzle approximately 3 to 6 from the surface of the part 4 6 Stop Blasting 4 6 1 To stop blasting remove foot pressure from the top of the...

Страница 15: ...low the dust collector damper Refer to the dust collector owner s manual the damper is located on the inlet on CDC 1 Dust Collectors and on the exhauster outlet on RPC 2 and RPH2Dust Collectors If the...

Страница 16: ...6 Cabinet Air Inlet Damper 5 6 1 Once the inlet damper is initially set per Section 2 7 it seldom requires readjustment The initial setting produces approximately 5 to 75 of static pressure in the ca...

Страница 17: ...ct one end of the 3 16 ID tubing to one of the tubing connectors elbows at the top of the manometer by pushing it over the barbed adaptor 5 8 3 Leave the needle protector on the needle and insert the...

Страница 18: ...king the readings replace the needle protector Close the manometer valves and store the manometer in the original container in a clean area NOTE If the manometer installation is permanent the manomete...

Страница 19: ...for media leaks Dust leaking from the inlet damper or other places on the cabinet indicates saturated filter cartridge Refer to the dust collector owner s manual 6 2 2 Check exhaust air for dust Dust...

Страница 20: ...on Quick change gloves are held in place using spring rings sewn into the attachment end of the glove To install insert the glove into the arm port so one spring is on the inside of the port and the o...

Страница 21: ...d 7 5 2 Remove the window and window frame per Section 7 6 7 5 3 Remove all the old gasket material and clean the surfaces of the cabinet and window frame 7 5 4 Peel a short section of adhesive backin...

Страница 22: ...f adhesive backing and adhere the strip gasket to the top edge of the light opening as shown in Figure 26 Press the gasket to bond Repeat the process for each side compressing the ends to seal 7 7 3 D...

Страница 23: ...e the leading edge of the wear plate is aligned with the reclaimer inlet as shown in Figure 27 and that the top edge is even with the top of the reclaimer 7 8 1 6 Install the front two sheet metal scr...

Страница 24: ...to secure Rearrange the clamp s as needed to press the wear plate against the reclaimer wall when installing NOTE The wear plate can also be installed by prying it against the wall as explained in Se...

Страница 25: ...elf drilling screws from the outside of the reclaimer remove the screws and lift the wall liner from the top of the reclaimer 7 9 11 Inner cone liners and cone ring liners are glued onto the inner con...

Страница 26: ...ignment 7 9 22 9th Place the cylinder liner over the inner tube Make sure the liner is tight against the top liner and use worm clamps to temporarily clamp the liner to the tube Tack weld the bottom o...

Страница 27: ...e the flex hose from the reclaimer top Figure 30 7 10 2 Remove the fasteners securing the reclaimer top and remove the top 7 10 3 Remove the two bolts three on 900 reclaimer that secure the baffle to...

Страница 28: ...cabinet hopper and reclaimer inlet or between the reclaimer and dust collector Replace hose and route it with as few bends as possible to prevent wear 8 1 9 Obstruction in flex hose between the cabine...

Страница 29: ...e mesh media in areas of high humidity Empty the media and store it in an airtight container when cabinet is not in use 8 5 5 A vibrator attached to the reclaimer hopper or media metering valve may he...

Страница 30: ...ockout and tagout electrical power and switch the motor leads as shown on the motor plate Refer to the system s wiring schematic Refer to Sections 2 5 1 and 2 5 2 8 13 2 Dust collector damper closed t...

Страница 31: ...rntable replacement 20 diameter 500 lb capacity 18329 30 diameter 500 lb capacity 21390 2 Bearing 1 1 2 bore 11517 3 Protector bearing 13479 4 Screw 1 2 NC x 1 1 2 cap 03454 5 Washer 1 2 lock 03516 6...

Страница 32: ...NP 220 Convent l with 600 reclaimer 14133 for BNP 220 Ergo model with 600 reclaimer 28892 for BNP 220 Convent l with 900 reclaimer 13949 for BNP 220 Ergo model with 900 reclaimer 28893 Rubber cabinet...

Страница 33: ...angle extension 12040 8 O ring side angle extension 08977 Figure 34 Reclaimer Liners Figure 35 Reclaimer must be designed to accept liners and have a removable top 600 cfm liners are for modular styl...

Страница 34: ...798 12 Plate hopper hose 21656 13 Gasket hopper plate 20247 14 Hose light lined flex specify ft required 4 ID for 300 cfm 7 ft required 12466 5 ID for 600 cfm 7 ft required 12467 6 ID for 900 cfm 9 ft...

Страница 35: ...Hose media clear specify ft required 12476 12 Wide spray nozzle Tungsten carbide No 6 11947 Boron carbide No 6 11934 No 8 11944 13 Wide spray nozzle nut Knurled brass 11916 Urethane covered 12906 14...

Страница 36: ...ut 1 4 20 hex 03111 8 Washer 1 4 lock 03117 9 Washer 1 4 flat 03116 Figure 40 9 7 Foot Pedal Assembly Figure 41 Item Description Stock No Foot pedal assembly less tubing includes items 1 thru 9 20483...

Страница 37: ...19231 10 Filter 1 2 manual drain air 01308 11 Adaptor 1 2 NPT x 1 2 flare 11351 12 Hose end 1 2 barb x 1 2 female swivel 15002 13 Hose end 1 2 barb x 3 8 male NPT 06369 14 Blow off nozzle 13116 15 Ai...

Страница 38: ...Parts Figure 44 Refer to Page 38 for 600 cfm reclaimer replacement parts and Page 39 for 900 cfm reclaimer replacement parts Item Description Stock No 300 cfm reclaimer with 5 outlet plate 28965 1 Gas...

Страница 39: ...odular 29524 14 Body section modular with door wear plate and baffle 29486 15 Body section modular with door rubber liners and Item 26 top plate 29495 16 Gasket 1 8 x 2 adhesive backed per foot 1 foot...

Страница 40: ...asket and latch 14271 13 Eyebolt 3 8 NC 00430 14 U channel 3 8 1 foot required 04076 15 Baffle 900 modular 23051 16 Gasket 1 8 x 2 adhesive backed per foot 1 foot required at this location 13089 17 Bo...

Отзывы: