Illustrations - Hot Gas Defrost - Low Temp • 47
ILLUSTRATIONS
Hot Gas Defrost - Low Temp
FIGURE 33: COIL 30" HOT GAS
ITEM #
PART NAME
1 COIL COVER
2 FAN
3 FAN HOUSING
4 COIL
5 CHECK VALVE
6 SERPENTINE
7 SLHX HEAT EXCHANGER
8 TXV VALVE
9 HAND VALVE (OPTIONAL)
10 DRIER (OPTIONAL)
11 CHECK VALVE
12 OPTIONAL DEFROST
TERMINATION SOLENOID
13 HOT GAS CLIP
14
DEFROST TERMINATION
PROBE LOCATION ON DUMP
LINE
E
8
10
9
11
7
13
6
5
12
4
3
2
1
14
30" HOT GAS DEFROST
DWG NO.SP-3000 REV. E
I/O MANUAL
TOLERANCES:
(PER SP-0457)
STANDARD
RELEASED
PART WEIGHT:
(IN LBS)
CAD DRAWING
NO MANUAL REVISIONS
COPYRIGHT INFORMATION
THIS DRAWING AND THE INFORMATION CONTAINED WITHIN, IS
THE SOLE PROPERTY OF ZERO ZONE, INC. ANY USE OF THIS
DOCUMENT OR DISCLOSURE OF ITS CONTENTS; BY
REPRODUCTION OR OTHER MEANS, WITHOUT THE WRITTEN
CONSENT OF ZERO ZONE, INC. IS STRICTLY PROHIBITED.
(NONE)
(NONE)
FINISH:
(PER SP-0154)
MATERIAL:
(PER SP-0404)
(UNLESS OTHERWISE SPECIFIED)
A
SHEET
SIZE
NOT TO SCALE
JHZ
SCALE:
MODELED BY:
DRAWN BY:
UNLESS OTHERWISE
SPECIFIED, ALL DIMENSIONS
ARE IN DECIMAL INCH
8/3/2012
E
1 OF 1
SP-3000
HOT GAS BYPASS VZ LAYOUT,
SHEET:
DATE:
REVISION
ZERO ZONE, INC.
110 NORTH OAKRIDGE DRIVE
NORTH PRAIRIE, WISCONSIN
USA 53153
DRAWING No:
DESCRIPTION:
BY
DATE
ECN No.
REVISION DESCRIPTION
No.
JHZ
11/26/2012
9651
REVISE BALLOON 14 DEFROST
E
REVISION INFORMATION
TERMINATION PROBE LOCATION
Содержание Highlight MERCHANDISER RHZC30
Страница 2: ......
Страница 4: ......
Страница 25: ...Illustrations Leveling 21 Illustrations Leveling Figure 3 Positioning Hat Channel Rails Refer back to page 5...
Страница 38: ...34 Illustrations Under Case Return Air Flow Illustrations Under Case Return Air Flow Figure 19...
Страница 39: ...Illustrations Penetration Sealing 35 Illustrations Penetration Sealing Figure 20...
Страница 40: ...36 Illustrations P trap Installation Illustrations Figure 21 45 ELBOW SUCTION LINE P trap Installation...