Installation & Operation • 9
INSTALLATION & OpERATION
GLASS SURFACES
Cleaning interior glass reduces fogging and increases visibility. Wipe down glass or plexiglass mirrors or ends with a glass cleaner. Do not use
any products containing silicone.
Shelf Location
The shelves are adjustable in 1" increments on cantilever shelf cases and may be located in any position for best display advantage.
Be sure brackets are completely seated.
Wire shelf brackets are stamped with “R” for Right and “L” for left to aid installation.
Shelves
Zero Zone manufactures many different styles of shelves, baskets, and product stops. The fully assembled shelves are installed in cases prior
to shipping. The bottom wire racks and baskets are placed on the shelves for shipping. Solid shelves have three parts: a solid center section
and two snap-in brackets. Some of the baskets may be reversed and used as a typical shelf.
Solid shelves can be disassembled for cleaning. A screwdriver can be used to spread the snap open to remove the brackets from the center
section.
Loading the Case
The case may be loaded with product after it has been operated for at least 24 hours with correct case temperature and proper control
operation. While loading the shelves, leave a minimum of 1" air space between the top of the product and the shelf above it so the customer
can remove the product. The air space allows an air curtain on top of the product. Product should not extend beyond the front of the shelves or
block the return air grill. The shelf loads are as follows:
ITEM
SHELF
DESCRIPTION
MAXIMUM LOAD
PER SHELF
1
22" and 24" deep
250 lbs.
2
4-Position Brackets
At 0°
250 lbs.
At 5°
250 lbs.
At 10°
150 lbs.
At 15°
100 lbs.
3
Heavy Duty
500 lbs.
Heavy duty shelves are available and are labeled as such.
Light Switch
The light switch is located on the ceiling on the right-hand side of the display case.
Case Thermometer
The cases are shipped with 2 thermometers. The first thermometer is factory-mounted in the discharge air stream. The second thermometer,
required by NSF, is shipped loose and should be installed in the warmest product location. Specific instructions are included.
Содержание Highlight MERCHANDISER RHZC30
Страница 2: ......
Страница 4: ......
Страница 25: ...Illustrations Leveling 21 Illustrations Leveling Figure 3 Positioning Hat Channel Rails Refer back to page 5...
Страница 38: ...34 Illustrations Under Case Return Air Flow Illustrations Under Case Return Air Flow Figure 19...
Страница 39: ...Illustrations Penetration Sealing 35 Illustrations Penetration Sealing Figure 20...
Страница 40: ...36 Illustrations P trap Installation Illustrations Figure 21 45 ELBOW SUCTION LINE P trap Installation...