TROUBLESHOOTING

 

 

IF THE APPLIANCE FAILS TO WORK:

 

 

Check the following points before calling for service:

 

 

1.   That the instructions for starting the appliance have been followed. 

 

2.   The appliance is level. 

 

3.   If it is possible to start the appliance on an alternative energy sources. 

 

4.   If the appliance fails to work on gas, check: 

a)   That the gas bottle is not empty. 
b)   That the regulator is not faulty. 
c)   If another appliance is connected to the same supply, check if it works 

properly. 

 

5.   If the appliance fails to work on 230V (Mains Electricity), check: 

a)   That the 230V supply is connected to the unit. 
b)   That there are no loose connections. 
c)   That the heating element has not burnt out. 
d)   Check if electric supply is on by feeling if hot air comes out of the top of the 

flue (chimney .This will take about 1 hour after switching on). 

 

IF THE APPLIANCE IS NOT COLD ENOUGH IT MAY BE BECAUSE:

 

 

1.   The ventilation of the absorption unit is inadequate.  Allow at least 100mm 

around Back, sides, and 600mm above. 

 

2.   The evaporator is frosted up 

– see Defrosting page 7. 

 

3  The gas pressure is incorrect 

– check the pressure regulator at the gas cylinder 

or at the jet (6) of the burner. (Page 9 

– Gas burner parts list). 

 

4   If the jet (6) is blocked, remove the jet, clean with alcohol or other solvent and 

blow through with compressed air.  Never use a piece of wire or a pin to clean 
the jet. (Page 9 

– Gas burner parts list). 

 

5  Check that you have the correct regulator for the cylinder and gas type that you 

are using. 

 

6     You have run out of gas. 

 

7.   The ambient temperature is too high. 

 

8.   Too many products are loaded into the freezer at one time 

– air must be able to 

circulate freely. 

 

9.   The lid is not properly closed or the lid seal is defective. 

 

10. The baffle has not been inserted into the chimney. (factory fitted) 

Содержание GEV60

Страница 1: ...THE ZERO MODEL GEV60 SINGLE LID CHEST FREEZER 3 WAY L P Gas 230V Electric 12V DC ZERO APPLIANCES PTY LTD Cat I3 28 30 37 I3B P 30 WARNING THIS APPLIANCE MUST BE EARTHED ENSURE THAT THE GAS SUPPLY HOSE...

Страница 2: ...tor size 0 42mm diameter marked 13 Gas consumption 34 2 g h Electrical Supply 230V Mains Electricity 0 130W This appliance is a single lid single bin chest type freezer and has a hanging storage baske...

Страница 3: ...ca may install a gas installation The installation must be installed in accordance with the requirements of SANS 10087 1 and any fire department regulations and or local bylaws applicable to the area...

Страница 4: ...pe by briefly pressing on the safety valve knob A This will ensure that the flame lights quickly Do not press knob A for more than 15 seconds see Users note BURN BACK FIRE IN BURNER TUBE OR CHAMBER RE...

Страница 5: ...ER BOX 1 Make sure that the electrical supply to the appliance is turned off 2 Open the shut off valve for the gas bottle or gas installation check that there is enough gas 3 Open flap B 4 Keep the fl...

Страница 6: ...sperse and then repeat the ignition steps TO START 12V DC OPERATION 1 Make sure that the gas supply to the appliance is turned off 2 Make sure that the electric 230V supply to the appliance is turned...

Страница 7: ...ll take about 1 hour after switching on IF THE APPLIANCE IS NOT COLD ENOUGH IT MAY BE BECAUSE 1 The ventilation of the absorption unit is inadequate Allow at least 100mm around Back sides and 600mm ab...

Страница 8: ...rner and re tighten the nuts on the thermocouple Repeat the starting instructions and lighting procedure as laid out on page 4 USER OPERATING INSTRUCTIONS TO START GAS OPERATION 14 If the appliance is...

Страница 9: ...oth and a small quantity of household detergent The lid seal should only be cleaned with soap and water and then thoroughly dried The absorption unit behind to the appliance should be cleaned with a b...

Страница 10: ...Smell or deposits indicate a leaking unit see User instructions Check the functioning of the flame failure control adjust if necessary Check the functioning of the ignition device if fitted adjust if...

Страница 11: ...areas GAS BURNER PARTS LIST 1 SANS BRASS HOSE TAIL 2 FLAME FAILURE DEVICE 3 M10 NUTS 4 M10 x 3 8 UNF JET HOLDER 5 M10 x 1 JET NUT 6 JET MARKED 13 7 MIXING TUBE 8 BURNER BOX 9 BURNER COVER 10 RETAINER...

Страница 12: ...Made in South Africa Pty Ltd...

Отзывы: