ZOM-12000-9v1
This manual contains proprietary information and is not to be copied or disclosed without written permission from
Zephyr International LLC.
Copyright 2002-2013 Page 11 of 24
BL-10300
Start Up
1. Install the Clevis Pin Hoist Mount, ZGS-12608-1 using the pins and
retaining pins
2. Install the BL-10300 hoist on the mount using the pins and retaining pins
3. Attach the hydraulic lines, insuring the up and down lines are attached
properly
4. Attach the electrical harness connector
5. Raise the mount into position, and install pins in load cells, lower chain
hoist to apply the load to the lead cells
6. Position the Zephyr GSE under the hoist
7. Pull out the E-Stop button to turn on power
8. Press the Pump Start button to start the hydraulic pump
9. Activate the hoist select switch on the motor starter panel to select the
BL-10300
10. Turn the Pressure switch to on, pressure should develop on the pressure
gage
11. Turn the Power switch on the control box to on, the load indicator should
illuminate
12. Press the Tare button on the load display to zero out the load with no
load on the cable
13. Pull up the locking ring on the Joystick controller and activate the hoist in
the extend direction
14. Attach the cable to the Zephyr GSE and operate the hoist in the down
direction
15. Follow the operating instructions for the Zephyr GSE while running the
hoist
Shut Down
16. Disconnect the cable from the Zephyr GSE
17. Retract the cable to full in and insure the full up limit switch activates and
the bumper compresses properly
18. Turn of the Power switch on control box
19. Turn the Pressure switch to off
20. Push in E-stop button
21. Raise the rescue hoist mount with the chain hoist and remove the pins
22. Lower hoist to lowest position
23. Detach the electrical harness connector
24. Detach the hydraulic lines
25. Remove the hoist from hoist mount and stow the pins properly