background image

12

www.zephyronline.com

SURFACE MAINTENANCE:

Do not use corrosive detergents, abrasive detergents or oven cleaners.   

 

 

 

 

 

Do not use any product containing chlorine bleach or any product containing chloride. 

 

 

 

 

Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface.    

Cleaning Stainless Steel

 

          

Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the 

stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.After cleaning use a non-abrasive 

stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton 

cloth or micro fiber cloth and buff in the direction of the stainless steel grain.  

 

Cleaning Black Stainless Steel

 

         

Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. To remove heavier grease build up 

use a liquid degreaser detergent.Due to a built-in layer of protective anti-smudge coating, do not use stainless steel polish/

cleaners to buff out black stainless steel. 

Aluminum Mesh Filters

The aluminum mesh filters installed by the factory are intended to filter out residue and grease from cooking.  They need 

not be replaced on a regular basis but are required to be kept clean.

Remove and clean by hand or in dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using 

phosphate detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is 

not covered by the warranty.  Spray degreasing detergent and leave to soak if heavily soiled.

Maintenance – 

Cleaning, Filter Care, Lights, Parts List

REPLACING LIGHT BULBS

CAUTION: Light bulb becomes extremely hot when turned on.

DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns.

Make sure all power is turned off and bulbs are not hot.

Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, 

 

stops and falls out.

If bulbs are difficult to turn due to prolonged use, firmly attach the provided glass suction cup to the bulb or use a rubber/

latex glove and turn counter clockwise.

LIST OF PARTS AND ACCESSORIES
DESCRIPTION  

PART#

Replacement Parts

Aluminum Mesh Filter  

50200059

Replacement Charcoal Filter 

Z0F-C091

Light Bulb, GU-10, 35W 

Z0B0023

Optional Accessories

Recirculating Kit 

ZRC-01OM

Duct Cover Extension Kit Stainless 

Z1C-01OMS

Duct Cover Extension Kit Black Stainless 

Z1C-01OMBS

Universal Make-Up Air Damper 

MUA006A

Bloom GU-10 LED, 6W 

Z0B0040

Baffle Filter Kit 

Z0F-B002

To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368

Содержание Ombra ZOM-E30ABS

Страница 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number APR19 0301 Zephyr Ventilation LLC Ombra ZOM E30AS ZOM E30ABS ZOM E36AS ZOM E36ABS...

Страница 2: ...www zephyronline com...

Страница 3: ...e 6 Ducting Options 7 Hood Specifications 8 Mounting the Range Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Capacitive Touch Controls 11 MAINTENANCE Cleaning Filter Care Lights Parts List 12 TRO...

Страница 4: ...the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie s...

Страница 5: ...I NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is us...

Страница 6: ...sion accessory Recirculating kit accessory HARDWARE PACKAGE CONTENTS MODELS ZOM E30AS ZOM E36AS ZOM E30ABS ZOM E36ABS PARTS SUPPLIED 1 Hood with internal blower 2 Aluminum mesh filters 1 Duct cover as...

Страница 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Страница 8: ...iency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover extens...

Страница 9: ...e unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting O...

Страница 10: ...com Installation Hood Specifications Standard min ducted 27 1 2 min recirc 32 max 42 1 2 Z1C 01OMS Z1C 01OMBS min ducted 46 1 2 min recirc 50 1 2 max 80 TOP FRONT SIDE 1 9 16 19 3 4 6 7 8 8 3 4 12 29...

Страница 11: ...the wall from inside the hood 7 Center and attach duct cover bracket to wall below ceiling or soffit using 2 6 x 1 1 2 screws 8 Install electrical 9 Install duct work and seal all joints with certifi...

Страница 12: ...to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal filters charcoal filter brackets and air diverter plate Hood Model Part...

Страница 13: ...tor illuminates 390 maximum CFM If speed two indicator illuminates 290 maximum CFM 2 Fan Speed Decrease Button Press this button to decrease fan speed 4 3 2 Q Quiet If fan is off press this button to...

Страница 14: ...ed on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher using a non phosphate detergent Discoloration of the filter may occur if using phosphate detergents or...

Страница 15: ...place 3 Check the installation of the hood The unit is whistling 1 The filter is not in the correct position 1 Adjust the filters until the whistling stops 2 The duct pipe connections are not sealed...

Страница 16: ...minates max 290 CFM When ACT is enabled the number of blower speeds will be reduced 390 CFM max 3 speeds and 290 CFM max 2 speeds There should also be a foil label located inside the hood body near th...

Страница 17: ...WN GREY YELL0W YELL0W RED RED AC120V GREEN BLACK WHITE WHITE BLACK BLACK WHITE WHITE FAN H FAN M FAN L LAMP CAP1 1 CAP2 2 AC N AC L YELL0W YELL0W 3 3 ACT 390 CFM Fan Max 2 5A ACT 290 CFM Fan Max 2 0A...

Страница 18: ...warranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION S...

Страница 19: ...nge hood at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures warranty co...

Страница 20: ...Guide d utilisation d entretien et d installation www zephyronline com Model number Serial Number APR19 0301 Zephyr Ventilation LLC Ombra ZOM E30AS ZOM E30ABS ZOM E36AS ZOM E36ABS...

Страница 21: ...www zephyronline com...

Страница 22: ...6 Options d installation pour le conduit 7 Sp cifications de la hotte 8 Montage de la hotte 9 Recirculation d air sans conduit 10 COMMANDES ET CARACT RISTIQUES Commandes 11 ENTRETIEN Nettoyage et ent...

Страница 23: ...ns surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R DUIRE LES RISQU...

Страница 24: ...section 1 la plus r cente dition du code C22 2 No 0 M91 ainsi que tous les codes et r glements en vigueur Si les codes permettent l utilisation d un fil de garde isol et que vous en utilisez un il est...

Страница 25: ...CONTENU DE LA TROUSSE DE QUINCAILLERIE MOD LES ZOM E30AS ZOM E36AS ZOM E30ABS ZOM E36ABS PI CES FOURNIES 1 Hotte avec ventilateur interne 2 Filtres d flecteurs 1 Ensemble de recouvrement de conduit pa...

Страница 26: ...rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable la longueur totale d un conduit d a ration ne devrait pas comp...

Страница 27: ...nibles consultez les exigences de hauteur d espace libre requise par le fabricant de la cuisini re ainsi que la hauteur recommand e de montage de la hotte au dessus de la surface de cuisson Informez v...

Страница 28: ...recirculation d air ne soit utilis e N utilisez que des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit avec des vis t le et isolez tous les joints avec du ruban adh sif en t...

Страница 29: ...fications de la hotte Standard min ducted 27 1 2 min recirc 32 max 42 1 2 Z2C 01OMS Z1C 01OMBS min ducted 46 1 2 min recirc 50 1 2 max 80 1 9 16 19 3 4 6 7 8 8 3 4 12 29 7 8 35 7 8 7 8 6 Devant de la...

Страница 30: ...des ancrages muraux et des vis convenables pour soutenir le poids de la hotte pourrait entra ner des blessures ou endommager la surface de cuisson ou le comptoir 6 Suspendez la hotte aux vis et serrez...

Страница 31: ...on lors de la recirculation d air TROUSSE DE RECIRCULATION D AIR REQUIS SI AUCUN CONDUIT N EST UTILIS L ensemble comprend des filtres charbon des supports de filtres charbon et un d flecteur d air Mod...

Страница 32: ...lumer le ventilateur la vitesse laquelle il tait en cours d utilisation lorsque vous avez teint la hotte 3 Augmentation de la vitesse du ventilateur Appuyez sur cette touche pour augmenter la vitesse...

Страница 33: ...filtre Si les filtres se d t riorent en raison de leur ge ou d une utilisation prolong e veuillez les remplacer par les pi ces suivantes REMPLACEMENT DES AMPOULES ATTENTION Les ampoules deviennent ex...

Страница 34: ...ent cesse 2 Les joints des tuyaux ne sont pas bien scell s ou les conduits ne sont pas connect s ad quatement 2 V rifiez les joints du conduit pour vous assurer qu ils sont ad quatement scell s Le mot...

Страница 35: ...ablage ou a un autre endroit visible NOTE Apres avoir modifie la position du cavalier et branche l appareil le debit de la hotte ne peut etre modifie a nouveau Pour v rifier si votre installateur a ac...

Страница 36: ...ES MAXIMUM SCHEMA DE CIRCUIT BLANC BLANC ROUGE ROUGE ROUGE GRIS BRUN BLEU JAUNE JAUNE JAUNE JAUNE JAUNE GRIS BRUN BLEU NOIR NOIR BLANC NOIR BLANC VERT 3 3 ACT 390 pi3 min Max du ventilateur 2 5 A ACT...

Страница 37: ...stall Un an apr s la date d achat originale du Produit vous tes galement responsable de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PA...

Страница 38: ...hyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la couverture de votre garantie si vous avez besoin de...

Отзывы: