Internal Blower Preparation
2. Secure internal blower to internal
blower flange by (4) M4*16 screws
from internal blower hardware.
1. Position internal blower inside
hood body so internal blower
collar protrudes through 6” round
flange opening.
3. Position capacitor box inside
hood body and secure by (2)
M4*8 screws from internal blower
hardware.
5. Connect 9 pin molex connector
from internal motor to 9 pin molex
connector from capacitor cable
box. Secure cable to hood interior
with zip tie and zip tie holder.
4. Secure ground wire from
capacitor box to ground wire rivet
nut next to capacitor box.
6. Connect 6 pin molex connector
from control board to 6 pin molex
connector from capacitor box
cable. Secure cable to hood
interior with zip tie and zip tie
holder.