Installation –
Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 6” round duct must be used to
PDLQWDLQPD[LPXPDLUÀRZHႈFLHQF\
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
8VHFDOFXODWLRQZRUNVKHHWWRFRPSXWHWRWDOGXFW
ZRUN3DJH
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 6” to 7” or 8”.
If turns or transitions are required: Install as far
away from duct opening and as far apart between
the two transitions as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
34”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORRVHSHUIRUPDQFHDQGHႈFLHQF\
If available, also refer to range manufacturer’s
height clearance requirements and recommended
KRRGPRXQWLQJKHLJKWDERYHUDQJH$OZD\VFKHFN
\RXUORFDOFRGHVIRUDQ\GLႇHUHQFHV
'XFWFRYHUH[WHQVLRQNLWDYDLODEOHIRUFHLOLQJ
heights up to 12 feet. Turn to page 19 for part
number and ordering information.
D
DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before
installation.
• If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
• If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHULIRWKHU
WKDQWKHFXVWRPHUUHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer
and installer.
26” min.
34” max.
min. A
min. B
max. C
min. D
min. E
max. F
Standard
Extension
Hood Heights
Duct Cover Duct Cove
r
minimum ducted (A) 26 1/2”
41 1/2“
minimum recirculating (B) 31”
45 1/2“
maximum (C) 50”
80”
Ceiling Heights
minimum ducted (D) 88 1/2” (7’ 4 1/2”) 103 1/2“ (8’ 7 1/2”)
minimum recirculating (E) 93” (7’ 9”)
107 1/2“ (8’ 11 1/2”)
maximum (F) 120” (10’) 150” (12’ 6”)
36”
Содержание Luce ZLU-E30BS
Страница 2: ...www zephyronline com...
Страница 19: ...17 Fan Curve Diagrams...
Страница 20: ...18 www zephyronline com Fan Curve Diagrams...
Страница 26: ...www zephyronline com...
Страница 43: ...17 Diagrammes des courbes caract ristiques des ventilateurs...
Страница 44: ...18 www zephyronline com Diagrammes des courbes caract ristiques des ventilateurs...