15
www.zephyronline.com
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close junction box cover.
20. Ducting version - Horizontal discharge ONLY:
Install the top cover.
Ductless (recirculating) version ONLY:
Remove the Knockout on top cover (to leave
passage of air from deflector) and install the top
cover.
Note:
The top cover should not be installed if is
intended to order and install the optional chimney
kit
Cutout
Conduit
21.
For
Ductless (recirculating) installations
Install one charcoal filter (available as an extra kit).
22.
Install metal filter and close the front door ((see
paragraph "Maintenance - Front Door" and
"Maintenance - Grease filter").
23.
Check all light bulbs to make sure they are secure
in their sockets.
Turn power on in service panel.
Inst
allation
Controls start flashing for about 15 secs to indicate
they are calibrating themselves, wait until flashing
stops (only
Motor touch sensor key OFF
(stand by)
is ON - see also paragraph "Controls").
Calibration is repeated any time the hoos is
disconnected intentionally or not from power supply
(i.e.: Black out).
Then check lights and blower operation.
If range hood does not operate:
•
Check that the circuit breaker is not tripped or the
house fuse blown.
•
Disconnect power supply. Check that wiring is
correct.